Laserfiche WebLink
proposed $500 per residential unit (total of 89 units) was determined to be sufficient <br />to mitigate for project impacts to the school district. Patrick Dehuff, Ed.D., Easton <br />School District Superintendent submitted a letter to Kittitas County on July 22, 2019 <br />stating that the proposed monetary mitigation is not sufficient and that the applicant <br />has not contacted to the school district as required and explained above. The <br />applicant must provide documentation regarding negotiations and agreement of <br />appropriate mitigation for the Easton School District to Kittitas County Community <br />Development Services to meet their obligations as outlined in Ordinance 2018-006. <br />Please update the draft Development Agreement and associated Exhibits <br />accordingly. Please see updated comments. <br />Public Works - Mark Cook, PE, Director, P: 509-962-7523, E: mark. cook&co.kittitas.wa.us <br />(Please see the attached Public Works Memo dated July 23, 2019. Each issue/item <br />identified within this memo must be addressed. Public Works comments have been <br />provided below for convenience.) <br />• Engineering: <br />1. Specify the quantity of campsites and RV sites. Please see DA Section 4. <br />2. Identify access to Lot 19 on the RV layout Illustration. Within record Pub. <br />Works Question #6. Attachment 2. <br />3. Pursuant to Ordinance No. 2018-006, Public Works' condition of approval I I <br />.3.9 requires a right-of-way (ROW) with sufficient width to allow for the storage <br />of snow within that space without impacting the travel lanes. Public ROW is 60" <br />wide plus additional land set aside (1 acre) as snow storage. See engr. Drawings <br />and Attachment 3. A question is ownership of this tract of land: condition # 18 <br />requires this to be dedicated Public ROW. <br />4. The second RV Layout Illustration and RV commercial maps show a fire lane of <br />14'. Fire lane must be 16'. Acknowledged. Attachments 3 & 4. <br />5. Private roads shall comply with the design requirements of 12.04.070 & <br />12.04.080 Table 4-4 of the Kittitas County 2015 Road Standards. See Exhibit D <br />to the Development Agreement and its attachments. We make numerous <br />references that roadway will comply with WADOT and KCC standards. <br />6. The extension off Meadows Way illustrates one access. A second access is <br />required if more than 30 (thirty) lots/units will use the private road per <br />12.01.095. Meadow Way is an in -network Kittitas County road way which <br />extends into a round -a -bout where private roads extend from and loop back to. <br />See engineered drawings and Attachment 3. <br />7. The Airport Safety Zone Map is unclear. Provide a legend defining each color. <br />Attachment 5. <br />8. Phasing is unclear. Clarify the specific phases in numeric order. The water tank <br />and looped water line will be constructed prior to any final platting. Once these <br />are in place, and with the extension of Meadow Way, differing portion of <br />platting can take place independent of other portions. See Exhibit F to the <br />Development Agreement. <br />