DESCRIPTION OF PROPOSE} WORKS
<br />The pnrposed work include a toal ofup to 100 wells, supplying up fo 1,000 gallons per minuie (gllm) ofwater for domestic supply for up
<br />to 145 residences, using al average of350 gallors per residence per day year-round, and irdgating up to 500 square feet (sq. ft.) per
<br />residence for a total of 1.664 irigated acres. The wells and places of use will be within the place of use desclibed above. This descnbes
<br />the total system and total water quantities and development authorized for this Swauk Watel Bank, in sum, utilizing dio eight (8) different
<br />groundwater sources ofsupply, under authority of8 permils, G4-35541-G4-35548.
<br />The authorized place of we is orvned by multiple private landowners. The intention of the combined applicants .is to obtain permib
<br />authorizing the use ofpublic groundwater in the requested amounts to be mjtigated by a portion ofthe 1877 First Creek Water Users
<br />Association water right. The l8?7 water rights provide water budget neutality, required by WAC 173-539A, for up to 145 nelv domestic
<br />uses within the defined portion ofthe Srvauk Creek subbasin.
<br />A mix of individual and small public water suppli systems will be developed-
<br />In sum, the total withdrawal ofwater from all 8 different groundwater sources shall not exceed the quantities authorized for the Swauk
<br />Creck Water Bank: up to 100 wells, up to 1,000 gpm ofwater for dornestic supply for up to 145 homes, including up to 500 sq. t. of
<br />irrigationpef residence for a total of 1.664 acres ofresidential inigation.
<br />October 31,2013 October 31, 2033
<br />PROVISIONS
<br />Gcneral
<br />You (applicant) will record with the Kittitas County Auditor a properly covenant as required under WAC 173-539A450 lhat restricts or
<br />prohibits tees or shrubs over a septic drain field.
<br />You (applicant) will record with
<br />interest in Trust W. ater Right Nos.
<br />the Kittitas County Auditor an conveyance insfinnent under which the applica$ obtaiDs ar
<br />CSa-00648(AA)sb4-b ard CS440648(AA)sb4-dA) to oftet consumptive use,
<br />Any valid priority calls against the source Trust Water fught.Nos, CS,l-00648(AA)sb4-b and CM40648(AA)sb4-c(A), based on local
<br />limitations in water availability, will result in temporary reduction or curtailment of the use until the priority call for water ends, or utrtil
<br />other mitigation is supplied as provided in the water moniloring and rnanagementplan.
<br />The Deparmlent ofEcolory cannot ensure that "a fonnation, a group offormations, or part ofa formation that contains suffioient saturaisd
<br />penneable malerial o yield economical [domestic] quantities ofwater to wells . . .!' will be encountered.
<br />The applicaut and each landowner (mitigation credit purohaser) shalt submit an assigument form to the Deparfirent ofEcolory describing
<br />the specifio interest of the mitigation oeditpurchaser in this pennit
<br />Prior to assignment ofany portion ofihis water to a third party, the permittee must submit and the Departnent ofEcolory must approve a
<br />wabr monitoring and manigemont plan consistent with the plan required for lhe two mitigaring tust water rights, CS440648(AA)sb4-b
<br />and CS440648(AA)sM-{A).
<br />Vy'ell Construction Requhements
<br />Because Groundwater finit t 1C+-:SSat) urd Groundwater Unit 2 (G4-35542) are marginal in nature, it is rccommended dru wells be
<br />located as far ftom each ofthese units' westem outer boundaries as possible. A minimum 100-foot spacing fiom existing wells is required
<br />in Units I and 2.
<br />Welis drilted grgg[ Groundwater Unit 3 (G4-35543) and into underlying Croundwater Unit 2 shall be requird at minimu$, to have a
<br />solid casing through Unit 3. Tlre location and construction of any well proposed within the E%SWIA of Section 34,
<br />1'. 20 N., R-l 7 E.Wlvl. must receive specific prior review and written approval ftom the Departrnont of Eccilory to ensure that water levels
<br />within Unit 3 in the vicinig ofthe Dunford and McCallum Springs will not be lowered by pumping from the new well.
<br />Wells drilled lltgggb Groundwater Unit 4 (G4:35544)and into an underlying unit shall be requked, at minimunr, to have a solid casing
<br />through Unit 4. A minimum 1O0-foot spachg from existing wells is required within the Unit 4 boundaries.
<br />Within the Unit 4 boundarieg specifically fiom the southern extent of Hidden Valley in tle NW% of Section 33, T.20 N', R. 1? EW.M',
<br />norfi to the northem boundary;fthe Foposed place ofuse for these eight permit applications ir the S% of Section 22 and extending into
<br />the SW% of Section 23, T. 20N., R 17 E.W.M.
<br />Wells drilled through Unit 4 into underhing goundwater rurits shall be cased and sealed a minimum of 100 feet into the underlying unit or
<br />io a deptb identifiedby the Depaltlnent ofEcologytechnical staffduring consultation prior lo drilling.
<br />Groundwater Unit 5 (G4-35545) has regiors where wells will encounter significant clays and likely r,esult in low yield and slow recovery
<br />wells. Additiomlly, ilnit 5 has areas ofperched and fiin saturated thicknesses. Therefore, a minimum 100-foot spacing from existing
<br />wells is required in Unit 5. Ifnew water users are not able to succcssfutly develop a well in Unit 5, they may instead _constdeldrilling into
<br />an underling grorndwatef unit, which depending on location, may be Unit 7 (G4-35547, central and north), Units I or 2 (south and
<br />southeast)orunitS(G4-35548,norttr). SuchwellsshallberequiredtohaveasolidcasingthroughUnit5.
<br />Wctts, Well Lngs, and Well Construction Standsrds
<br />All wells conshucted in dre state shall meet lho constmction requirements of WAC U3-160, titled "Minimum Shndards for the
<br />Conslruction and Maintenance of Wells" and RCW 18.104, titled *Water Well Constuction-" Any well which is unnable, abandoned, or
<br />whose use has been permanently discontinued, or which is in such disrepair thet its continued use is impractical or is an environmental'
<br />safety or pubtic health hazard, shall be decommissioned-
<br />PERMIT WRTS FiIe No' G4-35546It
<br />October 3 l, 2032
<br />COMPLETE
|