DNSCRIPTION OF PROPOSI:D WOIIKS
<br />The proposed works include a total of up to 100 wells, supplying up to 1,000 gallons per minute (gpm) of water for domestic supply for up
<br />to 145 residences, using an average of350 gallons per residence per day year-round, and inigating up to 500 squaro feet (sq. ft.) per
<br />residence for a total oft.664 irrigated aqes. The wells atrd places ofuse will be within the place ofuse described above. This describes
<br />the total system and tolal water quantities and development authorized for this Swauk Water BzuJg in sum, utilizing tJre I different
<br />groundwater sources ofsupply, urder authority ofeight (8) pennits, G4-35541-G4-35548.
<br />the authorized place of use is owned by multiple privats latrdowners.
<br />'The intention of the combined applicants is to obtain pemits
<br />authorizing the use ofpublic groundwater in the request€d amounts to be mitigated by a portion of the 1877 Fimt Creek Water Users
<br />Association water righr The 1 8?7 water righls provide water budget neubality, required by WAC 173-539 A, for up lo 145 new domestic
<br />uses rvithin the de{ined portion ofthe Swauk Creek subbasin.
<br />A mix of irrdividual and small public water supply systems will be developed.
<br />lr1 sum, the total withdrawal ofwater fronr all 8 different grounawater sources shall not exceed the quantities authorized for the Swauk
<br />Creek Water Bank; up to 100 wells, up to 1,000 gpm ofwater for domestic $upply for up to i45 homes, including up to 500 sq. fi. ol
<br />irrigation per residence for a tolal of 1.664 acres oflesidential inigation.
<br />DEVELOPMENTSCHEDULS
<br />FULL
<br />October 3 t, 2013 October 3 1, 2033
<br />General
<br />You (applicant) will record with the Kittitas County Auditor a properly covenant as required under WAC i73-539A-050 that restricts or
<br />prohibits trees or shrubs over a septic drain field.
<br />You (applicant) will record with the Kittitas Crunty Auditor an appropriate conveyance inskument under which the applicant obtains an
<br />interest iri Trust Water Right Nos. CS,l-00648(AA)sb4-b and CS4-00648(AA)sb4-c(A) to offset consumptive use.
<br />Any valid priority calls against the source Trust Water Rigbt Nos. CS4-00648(AA)sb4-b and CS4-00648(AA)sb4-c(A), based on local
<br />limitations in water availabilrty, wil result in ternporary reduction or cwtailment ofthe use until the priotity call for water ends, or until
<br />other mitigation is supplied as provided in the water monitoring and management plan.
<br />The Depaltnent of Ecolory cannot ensure that 'h formation, 4 group of formations, or part of a fomation tha! contains suficient saturated
<br />permeable material to yie ld economical [domestic] quantities of water to wells . . ." will be encountered.
<br />The applicant and each landowner (mitigation oredit purchaser) shall submit an assignment form to the Deparhent of Ecolory descnbtlg
<br />t}e speci-fic interest of ttre mitigation credit purchaser in this permit.
<br />. Prior to assignment of any portion of this water to a third party, the p€rmittee must submit and the Departrnent of Ecologr must-approve a
<br />water monit6ring and manigcment plan consistent with the plan required for the two mitigating irust water rights, CS4-00648(AA)sb4-b
<br />and CS440648(AA)sb4-c(A).
<br />Well Construction Requiremenls
<br />Because Groundwater Unit I (G4-35541) and Grouldwater Unit 2 (G4-35542) are marginal in naturg it is recommended that wells be
<br />located as far from each of these unis' westem outer boundaries as possible. A minimum lO&foot spacfug from oxisting wells is required
<br />in Units I and2.
<br />Wells drilled throush Groundwater Udt 3 (G4-35543) and into underlying Croundwater Unit 2 shall bo required, af minimurn" to have a
<br />solid casing through Unit 3. The location and consfuction of any well proposed witbin the E%Sll//c of Section 34,
<br />T. 20 N., R lZ E.WM. must receive specific pnor r,eview and written approval from the Deparhent of Ecology to ensure that water levels
<br />wirhin Unit 3 in the vicinity of the Dunford and McCallum Springs will not be lowered by pumping from ihe new well.
<br />Wells driued !!&gg[ Croundwater Unit 4 (G4-35544) and into an underlying unit shall be requked, at minimum, to have a solid casing
<br />tfuough Urit 4. A Udnimum 1O0-foot spacing &om existing wells is required widrin the Unit 4 boundaries.
<br />Wihin the Unit 4 boundaries, specificaily from thc southern extent of Hidden Valley in the NW% of Section 33, T. 20 N., R. 17 E.W.M.,
<br />north to the norfhern boundary ofthe proposed place ofuss for these eight permit applications in the S% ofSection 22 and extending into
<br />the SW% of Section 23, T. 20 N., R. 17 E.WM.
<br />Wells drilled l3lgggb Unit 4 into underlying goundwater units shall be cased and sealed a minimum of t00 feet into the underlying unit or
<br />to a depth identified by the Departnent of Ecology technical staff during consultation prior to &illing.
<br />Groundwater Urdt 5 has regions where wells will encounter significant clays and likeiy resdlt in low.yield and slow recovery wells.
<br />Additionally, Unit 5 has areas of perched and thin saturarcd fiicfossses. Therefore, a minimum 100-fodt spacing from existing wells is
<br />requked in Unit 5. If new water us€rs are not able to successfirlly develop a well in Unit 5, they may instead coasider drilling into an
<br />mderlying groundwater unit, whicf, depending on location, may be Unit 7 (G4-35547, central and north), Units I or2 (south and soutbeast)
<br />or unit 8 (c4-35548, north). such wells shall be required to have a solid casing tbrough unit 5.
<br />Wclls, Well Logs, and Well Construction Standards
<br />All wells consilcted in thc state shall meet the construstion requirements of WAC 173-160, titled 'Minimum Standards for the
<br />Construcrion aod Maintenance of Wells' and RCW 18.104, titled "Wafer Well Consu:uction" Any well which is unusablq abandoned, or
<br />TfiIS DATE:
<br />October 3 1, 2032
<br />PERMIT I I WRTS FileNo. G4-35543
|