4.O4 Civil Sheet C- <br />3 <br />Sheet C-3 Add the following note to drawing Sheet C-3: <br />Curb and gutter will be required on both sides of the <br />Transfer Building access road starting at the entrance to <br />the Transfer Building north for 235 LF (470 Lt total). <br />Contractor to coordinate with Owner and Engineer for <br />final curb and gutter location. <br />4.05 Specification <br />00 43 01 <br />Measurement <br />and Payment <br />00 43 01 ln Part 3, under 3.O - Bid ltem #15 - Site Signage, add <br />thermoplastic stop bars to lump sum price. <br />4.06 Specification <br />09 29 00 <br />Gypsum <br />Board <br />09900 ln Section 09 9 00, change the following: <br />Paragraph 2.028 - (GB) 5/8" Type C, Change to 5/8" Type <br />X <br />The following items are not used on this project and shall <br />be deleted from Specification Section 09 9 00: <br />Defete paragraph: 2.0I, A.2 <br />Delete paragraph: 2.02,8.5 <br />Delete paragraph, 2.02 8.5.5 <br />Delete paragraph, 2.02 C <br />Delete paragraph 2.02D <br />Delete paragraph 2.02E <br />Delete paragraph 2.02D <br />Delete paragraph 3.01. 15 <br />Delete paragraph 3.01. 16 <br />Revise paragraph 3.01D.2. Provide a level4 finish <br />4.O7 Specification <br />09 22L6 <br />09 22L6 Provide flat bar backing per E.3b. Other backing is <br />provided as an option to the contractor. <br />4.08 Specification <br />TO 8L 12 <br />Bird Control <br />Devices <br />10 8t 12 Bird netting not required. Delete references to bird <br />netting: <br />Delete paragraph: 1.3 <br />Delete paragraph: 2.07C <br />Delete paragraph: 2.03 <br />4.09 Hot Mix <br />Asphalt <br />Special <br />Specifications <br />5-04 <br />5-04 Add the following: to Special Specification 5-04: <br />All asphalt shall have a nominal aggregate size of %-inch <br />END OF ADDENDUM NO.4 <br />Page 2 of 3