My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Finalized Contract Agreement Packet
>
Meetings
>
2024
>
09. September
>
2024-09-03 10:00 AM - Commissioners' Agenda
>
Finalized Contract Agreement Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/8/2024 12:50:20 PM
Creation date
10/8/2024 12:48:44 PM
Metadata
Fields
Template:
Meeting
Date
9/3/2024
Meeting title
Commissioners' Agenda
Location
Commissioners' Auditorium
Address
205 West 5th Room 109 - Ellensburg
Meeting type
Regular
Meeting document type
Fully Executed Version
Supplemental fields
Item
Request to Approve a Contract with Belsaas & Smith Construction for the Lower Valley Transfer Station
Order
11
Placement
Consent Agenda
Row ID
121755
Type
Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
194
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1) Sheet 8603 & E701 -The <br />electrical panel PP-ASP is <br />changed from a 120/208V 3ph <br />panel to a277/48OY 3ph panel <br />as shown on the one-line and <br />in the schedules. <br />2l Sheet E701" - There is a minor <br />adjustment on the one-line for <br />the main switchboard - two <br />circuit breakers have been <br />updated to the correct size and <br />location. <br />3) Sheet E701 - The notes indicate <br />the irrigation pump enclosure <br />will require a stepdown <br />transformer and it is identified <br />as being supplied by the <br />irrigation pump ma nufacturer. <br />4l Drawing E200 was added to <br />identify the required conduit <br />and wiring for the aeration and <br />recirculation pump power and <br />controls. <br />T.L2,I Revised Civil Drawings Sheets C20,C24, <br />c27 <br />Revised drawings are added to <br />Addendum No. 1. <br />1.13 Revised Specification <br />Section 40 95 13 Control <br />Panels, VFDS, and RMC <br />Section 40 95 13 Revised specification is added to <br />Addendum No. 1. <br />1.r4 Water Recirculation <br />System Specification <br />Section 40 95 1,4 New specification is added to <br />Addendum No. 1 for Leachate Pond <br />water recirculation system. <br />1.15 Dewatering Section 0L 50 00 <br />Part 1.9, <br />Subsection B <br />Add following statement at the end of <br />the paragraph of Part L.9, subsection B <br />in Section 01 50 00: <br />lf dewotering is required, the <br />Contractor will be required to build <br />temporary sedimentation Ponds or <br />sedimentation trap BMPs which <br />discharge to the proiect storm system <br />in accordance with Stote of Woshington <br />- Deportment of Ecology - 2079 <br />Stormwote r Mo nage ment M a n uol for <br />Edstern Woshington, Chopter 7, <br />Element #10, Page 769. Alternotely, <br />BMPs con drain to o temporary grovity <br />or pumped conveyance system draining <br />Page 3 of 5