My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2024 Staff Report and Docket Item Supporting Documents
>
Meetings
>
2024
>
09. September
>
2024-09-10 6:00 PM - Planning Commission
>
2024 Staff Report and Docket Item Supporting Documents
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/5/2024 2:25:00 PM
Creation date
9/5/2024 1:28:45 PM
Metadata
Fields
Template:
Meeting
Date
9/10/2024
Meeting title
Planning Commission
Location
Commissioners' Auditorium
Address
205 West 5th Room 109 - Ellensburg
Meeting type
Regular
Meeting document type
Supporting documentation
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
provide fire flow or automatic sprinklers for residential development on lots that average <br /> more than thirty-five thousand square feet in size,but shall meet the International <br /> Wildland-Urban Interface Code as adopted and amended by Kittitas County except <br /> where said code requires automatic sprinklers and/or fire flows. <br /> I 5. The it current edition of the Uniform Plumbing Code(UPC), _� ,ate published by the International Association of <br /> Plumbing and Mechanical Officials as adopted and amended by the State of Washington in Chapter 51-56 WAC and Chapter <br /> 51-57 WAC. <br /> I 6- The mosi curcur e� Washington State Energy Code,29 Ed+tief asset forth in Chapter 51-11 WAC,Chapter 51- <br /> 11C WAC(Commerciap and Chapter 51-11R(Residential). <br /> 7. The most current edition of the International Property Maintenance Code(IPMC), ^' An as published by the <br /> International Code Council. <br /> B. The most current lion of the International Wildland Urban Interface Code, a'*' ,as published by the <br /> International Code Council;with the following adopted appendices and amendments: <br /> a. Appendix B:Vegetation Management Plan <br /> b. Appendix C:Fire Hazard Severity Form <br /> c. Amendments to the Wildland Urban Interface code specific to Kittitas County shall be located in KCC Title 20. <br /> 9. The mot _ -_ _._ International Swimming Pool and Spa Code(ISPSC),ZM-€dWen as published by the <br /> International Code Council. <br /> (Ord.2023-010,2023;Ord.2021-003,2021;Ord.2018-005,2018;Ord.2017-001,2017;Ord.2016-012,2016;Ord.2013-013,2013,Ord. <br /> 2013-006,2013;Ord.2011-001,2011;Ord.2010-010,2010;Ord.2010-003,2010;Ord.2008-22,2008;Ord.2007-29,2007;Ord.2007-19, <br /> 2007;Ord.2004-18,2004,Ord.98-23,1998,Ord.95-7,1995;Ord.93-4,1993;Ord.92-29,1992;Res.84-29,1984) <br /> 14.04.020 General requirements. <br /> 1. Conflict between Codes:Whenever there is a conflict between a Referenced Code in Section 14.04.010 of this code and the <br /> General Requirements contained in Section 14.04.020 of this code,the General Requirements shall apply. <br /> 2. Table R301.2(1),Climatic and Geo ra hic Desi n Criteria,of the International Residential Code,is amended as follows: <br /> vROUNG' ,zTFi1F:L DESIGN SySS&IIC 0 17UPEC3 T^�6t;� L -.'v'P T R ICE BARRIER FLOOD AIR MEAN <br /> i OYr DESIGN FaCryx ?i.3CGN UNDERLAYMENT IWARW FREEZING ANNUAL <br /> Speed^Iraphf 'lopagrspilic Special Fllud- CATEGORY' VVeat eriag• Frost Termit TEnIP REQUIRED' INDEX TEMP <br /> efforts` wind borne line <br /> region' debris depth" <br /> zone <br /> Case 110 V ult No No No C,DO,D1, Severe 24" Slight to 2°F Yes Date 1,000-2,000 50°F <br /> Moderate Entered <br /> study Into NFIF: <br />
The URL can be used to link to this page
Your browser does not support the video tag.