My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ord-2021-016
>
Meetings
>
2021
>
12. December
>
2021-12-07 10:00 AM - Commissioners' Agenda
>
Ord-2021-016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/9/2021 3:06:41 PM
Creation date
12/9/2021 3:05:21 PM
Metadata
Fields
Template:
Meeting
Date
12/7/2021
Meeting title
Commissioners' Agenda
Location
Commissioners' Auditorium
Address
205 West 5th Room 109 - Ellensburg
Meeting type
Regular
Meeting document type
Fully Executed Version
Supplemental fields
Item
Request to Approve an Ordinance for Amendments to Kittitas County Code Title 17A, Critical Areas
Order
30
Placement
Consent Agenda
Row ID
83921
Type
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
areas and avoid the need for channel dredqinq or dikino or other maintenance <br />activities that have the potential to substantially deqrade river and stream functions. <br />b. Residentialand CommercialDevelopments. Permanent residentialstructures and <br />commercial developments shall be allowed in alluvial fan hazard areas only if the <br />alluvial fan has undergone a County-approved studv to assess potential hazards, <br />determine risks. and identify mitioation measures and is deemed suitable for <br />development. The Director shall make this determination based on a detailed <br />assessment by a qualified enqineer. enoineerinq geoloqist. or geoloqist. licensed in <br />the state of Washinqton, that identifies the risks associated with a 500-vear return <br />period debris flow or the maximum credible event that could impact the alluvial fan.c. Accessory Structures. Accessory structures not involvinq human occupancv shall <br />be allowed. <br />17A.06.070 SeismicHazardStandards <br />1. Permitted Alterations and Development. Alterations and development within seismic <br />hazard areas shall follow the provisions of the Kittitas Countv-adopted version of the Uniform <br />Buildino Code. Alterations and development within seismic hazard areas shall not require the <br />submission of a geologically hazardous area risk assessment or geotechnical report. <br />17A.06.080 Volcanic Hazard Areas <br />1. Permitted Alterations and Development. Because volcanic hazards in Kittitas Countv are <br />limited to ash deposition. alterations and development located only within volcanic hazard <br />areas. and not other qeoloqicallv hazardous areas, shall not require the submission of a <br />geoloqicallv hazardous area risk assessment or qeotechnical report. <br />174.06.090 Mine Hazard Areas <br />1. Alteration. There are no additional protection standards for mine hazard areas: the <br />standards of KCC 17A.06.030 shall apply. <br />17A.06.100 Reportinq <br />1. Geoloqicallv Hazardous Area Risk Assessment . lf a proposed development is located <br />within or adjacent to a known or suspected landslide. mine. alluvial fan. or erosion hazard <br />area. the applicant shall submit a Geoloqicallv Hazardous Area Risk Assessment prepared <br />bv a qualified professional qeoloqist or enqineering qeoloqist. No further analvsis shall be <br />required if the Geoloqicallv Hazardous Area Risk Assessment concludes that the alteration <br />or development is not at risk from potential qeoloqic hazards. and that there is no qeoloqic <br />hazard present on or adjacent to the site. <br />lf the Geoloqically Hazardous Area Risk Assessment and/or the Director concludes that a <br />qeolooically hazardous area is located on or adjacent to the alteration or development and/or <br />the alteration or development is at risk from ootential qeoloqic hazards. the aoplicant shall <br />submit a Geotechnical Report consistent with the provisions of KCC 174.02.370, <br />andprepared bv a qualified enqineer or enqineerinq qeologist. <br />2. Geoloqicallv Hazardous Area Risk Assessment Contents. When required bv this <br />Chapter. Geoloqicallv Hazardous Area Risk Assessments shall include the oeneral critical <br />areas report requirements of KCC 17A.01.080 in addition to the followinq: <br />a. A description of the qeoloqy of the site and the proposed develooment: <br />b. An assessment of the potential impact the proiect may have on the qeoloqic hazard: <br />c. An assessment of what potential imoact the qeologic hazard mav have on the <br />proiect: <br />d. Appropriate mitigation measures. if any: <br />e. A conclusion as to whether further analvsis is necessary: andf. The signature and stamp of the engineering qeoloqist. or qeoloqist that prepared the <br />assessment. <br />55
The URL can be used to link to this page
Your browser does not support the video tag.