BUILDING PLANNING <br />illumination of 6 footcandles (65 lux) over the area <br />of the room at a. height of 30 inches (762 mm) above <br />the floor level. <br />3. Use of sunroom and patio covers, as defined in Sec. <br />tion R202, shall be permitted for natural ventilation if <br />in excess of 40 percent of the exterior sunroorn walls <br />are open, or are enclosed only by insect screening. <br />R303.2 Adjoining rooms. For the purpose of determining <br />light and vent7latlon requirements, any room shall be consid- <br />ered to be a portion of an adjoining room where not less than <br />one-half of the area of the common wall is open and unob- <br />structed and provides an opening of not less than one-tenth of <br />the floor area of the interior room and not less than 25 square <br />feet (2.3 mz). <br />Exception: Openings required for light or ventllation shall <br />be permitted to open into a sunraom with thermal isolation <br />or a patio cover, provided that there Is an openable area <br />between the adjoining room and the sunroom or patio <br />cover of not less than one-tenth of the floor area of the <br />interior room and not less than 20 square feet (2 rn j. The <br />minimum openable area to the outdoors shall be based <br />upon the total floor area being ventilated. <br />R303.3 Bathrooms. Bathrooms, water closet compartments <br />and other similar rooms shall be provided with aggregate glaz- <br />ing area in windows of not less than 3 square feet (0.3 m�, one- <br />half of which must be openable. <br />Exception: The glazed areas shall not be required where <br />artificial light and a local exhaust system are provided. <br />The minimum local exhaust rates shall be determined in <br />accordance with Section M1507. Exhaust air from the <br />space shall be exhausted directly to the outdoors. <br />R303.4 Mechanical ventilation. Where the air infiltration <br />rate of a dwelling unit is 5 air changes per hour or less where <br />tested with a blower door at a pressure of 0.2 inch w.c (50 Pa) <br />in accordance with Section N1102.4.1.2, the dwelling unit <br />shall be provided with whole -house mechanical ventilation in <br />accordance with Section M1507.3. <br />2. Vents and chimneys serving fuel -burning appli- <br />ances shall be terminated in accordance with the <br />applicable provisions of Chapters 18 and 24. <br />3. Clothes dryer exhaust ducts shall be terminated in <br />accordance with Section M1502.3. <br />8.303.5.2 Exhaust openings. Exhaust air shall not be <br />directed onto walkways. <br />R303.6 Outside opening protection. Air exhaust and intake <br />openings that terminate outdoors shall be protected with cor- <br />rosion -resistant screens, louvers or grilles having an opening <br />size of not less than'!, Inch (6 mm) and a maximum opening <br />size of V, inch (13 mm), in any dimension. Openings shall he <br />protected against local weather conditions. Outdoor air <br />exhaust and intake openings shall meet the provisions for <br />exterior wall opening protectives in accordance with this <br />code. <br />R303.7 hiterlor stairway illumination. Interior stairways <br />shall be provided with an artificial light source to illuminate <br />the landings and treads. The light source shall be capable of <br />illuminating treads and landings to levels of not less than i <br />foot-candle (11 lux) as measured at the center of treads and <br />landings. There shall be a wall switch at each floor level to <br />control the light source where the stairway has six or more <br />risers. <br />Exception: A switch is not required where remote, central <br />or automatic control of lighting is provided. <br />R303.7.1 Light activation. Where lighting outlets are <br />Installed In interior stairways, there shall be a wall switch <br />at each floor level to control the lighting outlet where the <br />stairway has six or more risers. The illumination of exte- <br />rior stairways shall be controlled from Inside the dwelling <br />unit. <br />Exception: Lights that are continuously illuminated or <br />automatically controlled. <br />R303.8 Exterior stairway illumination. Exterior stairways <br />shall be provided with an artificial light source located at the <br />11303.5 Opening location. Outdoor intake and exhaust open- <br />top .Landing of the stairway. F..xterlor stairways providing <br />access to a basement from the outdoor grade Ievel shall be <br />ings shall be located in accordance with Sections R303.5.1 <br />provided with an artificial light source located at the bottom <br />and R303,5.2. <br />landing of the stairway. <br />8303.5.1 Intake openings. Mechanical and gravity out- <br />R303.8.1 Sunroom additions. Required lazed <br />g openings <br />door air intake openings shall be located not less than 10 <br />shall be permitted to open into sunroom additions or patio <br />feet (3048 mm) from any hazardous or noxious contanmi- <br />covers that abut a street, yard or court if in excess of 40 <br />nant, such as vents, chimneys, plumbing vents, streets, <br />percent of the exterior sunroom walls are open, or are <br />alleys, parking lots and loading docks, <br />enclosed only by insect screening, and the ceiling height <br />For the purpose of this section, the exhaust from dwell- <br />ing unit toilet room7' <br />bathrooms and kitchens shall not be <br />sunrow ds -not. m tharL T feet ,(2134 mm). <br />R303.9.Required <br />considered as hazardous or noxious. <br />heating. Where the winter design tempera - <br />ture in Table R301.2(1) is below 60°F (16* C), every dwelling <br />Exceptions: - <br />unit shall be provided with heating facilities capable of main - <br />1. The 10 -foot (3048 mm) separation is not required <br />twining a room temperature of not less than 68°F (20aC) at a <br />point 3 feet (914 mm) above the floor and 2 feet (610 mm) <br />where the intake opening is located 3 feet (914 <br />mm) or greater below the contaminant source. <br />from exterior walls in habitable rooms at the design tempera- <br />ture. The installation of one or more portable space heaters <br />shall not be used to achieve compliance with this section. <br />56 2015 INTERNATIONAL RESIDENTIAL CODE' <br />1 E Coprdght C x014 SCC. ALL RIGHTS RESERVED. A—Mid by Milted Floryon Mar 4, 2016 4 3 457 1114 PMnl to Llanse Agrermentwith ICC. No fi rtha r.produrtian or <br />dktd; uttan autharl d. ANY UNAUTHORIZED REPRODUCTION ORD1S7R1RMON IS A VIOLATION OP ME FEDERALCOPYRIGNTACT AND nIELICE,NSE <br />AGREEMENT, AND SURJECTTO CIVIL AND CRIMINAL PENALrFS TnrPxbNDm <br />