Laserfiche WebLink
DEFINITIONS <br />[RBJ MASONRY, SOLID. Masonry consisting of solid <br />masonry units laid contiguously with the joints between the <br />units filled with mortar. <br />[RB] MASONRY UNIT. Brick, tile, stone, architectural cast <br />stone, glass block or concrete block conforming to the <br />requirements specified in Section 2103 of the Tnterriational <br />Building Code. <br />Clay. A building unit larger in size than a brick, composed <br />of burned clay, shale, fire clay or mixtures thereof. <br />Concrete. A building unit or block larger in size than 12 <br />inches by 4 inches by 4 inches (305 mm by 102 mm by <br />102 mm) made of cement and suitable aggregates. <br />Glass. Nonload-bearing masonry composed of glass units <br />bonded by mortar. <br />Hallow. A masonry unit with a net cross-sectional area in <br />any plane parallel to the loadbearing surface that is less <br />than 75 percent of its gross cross-sectional area measured <br />in the same plane, <br />Solid. A masonry unit with a net cross-sectional area in <br />every plane parallel to the loadbearing surface that is 75 <br />percent or more of its cross-sectional area measured in the <br />same plane. <br />[RE] MASS WALL. Masonry or concrete walls having a <br />mass greater than or equal to 30 pounds per square foot (146 <br />kg/ml, solid wood walls having a mass greater than or equal <br />to 20 pounds per square foot (98 kg/ml, and any other walls <br />having a heat capacity greater than or equal to 6 Btu/fe • °F <br />1123 J/(rn' - K)]. <br />[RB] MEAN ROOF HEIGHT. The average of the roof eave <br />height and the height to the highest point on the roof surface, <br />except that eave height shall be used for roof angle of less <br />than or equal to 10 degrees (0.18 rad). <br />MECHANICAL DRAFT SYSTEM. A venting system <br />designed to remove flue or vent gases by mechanical means, <br />that consists of an Induced draft portion under nonpositive <br />static pressure or a forced draft portion under positive static <br />pressure. <br />Forced -draft venting system. A portion of a venting sys- <br />tem using a fan or other mechanical means to cause the <br />removal of flue or vent gases under positive static pres- <br />sure. <br />Induced draft venting system. A portion of a venting <br />system using a fan or other mechanical means to cause the <br />i. <br />removal of flue or vent gases under nonpositive static vent <br />pressure. <br />Power venting system. A portion of a venting system <br />using a fan or other mechanical means to cause the <br />removal of flue or vent gases under positive static vent <br />pressure. <br />MECHANICAL, EXHAUST SYSTEM. A system for <br />removing air from a room or space by mechanical. means. <br />MECHANICAL JOINT. <br />1. A connection between pipes, fittings or pipes and fit- <br />tings that is not welded, brazed, caulked, soldered, sol- <br />vent cemented or heat -fused. <br />2. A general form of gas- or liquid -tight connections <br />obtained by the joining of parts through a positive hold- <br />ing mechanical construction such as; but not limited to, <br />flanged, screwed, clamped or flared connections. <br />MECHANICAL SYSTEIVI. A system specifically addressed <br />.d and regulated in this code and composed of components, <br />devices, a_ppllances_and egument. _. <br />[RB] METAL ROOF PANEL. An interlocking metal sheet <br />having an installed weather exposure of not less than 3 square <br />feet (0.26 nil per sheet. <br />[RB] METAL ROOF SHINGLE. An interlocking metal <br />sheet having an installed weather exposure less than 3 square <br />feet (0.28 mper sheet. <br />[RB] MEZZANINE, An intermediate level or levels <br />between the floor and ceiling of any story. <br />[RB] MODIFIED BITUMEN ROOF COVERING. One or <br />more layers of polymer modified asphalt sheets. The sheet <br />materials shall be fully adhered or mechanically attached to <br />the substrate or held in place with an approved ballast layer. <br />[RB] MULTIPLE STATION SMOKE ALARM. Two or <br />more single station alarm devices that are capable of inter- <br />connection such that actuation of one causes all integral or <br />separate audible alarms to operate. <br />[RBI NAILABLE SUBSTRATE. A product or material <br />such as framing, sheathing or furring, composed of wood or <br />wood -based materials, or other materials and fasteners pro- <br />viding equivalent fastener withdrawal resistance. <br />NATURAL DRAFT SYSTEM. A venting system designed <br />to remove flue or vent gases under nonpositive static vent <br />pressure entirely by natural draft. <br />[RBJ NATURALLY DURABLE WOOD. The heartwood <br />of the following species with the exception that an occasional <br />piece with corner sapwood is permitted if 90 percent or more <br />of the width of each side on which it occurs is heartwood. <br />Decay resistant. Redwood. cedar, black locust and black <br />walnut. <br />Termite resistant. Alaska yellow cedar, redwood, Eastern <br />red cedar and Western red cedar including all sapwood of <br />Western red cedar. <br />[RBI NONCOMBUSTIBLE MATERIAL. Materials that <br />pass the test procedure for defining noncombustibility of ele- <br />mentary materials set forth in ASTM E 136. <br />[RB] NOSING. The leading edge of treads of stairs and of <br />landings at the top of stairway flights. <br />[RB] OCCUPIED SPACE. The total area of all buildings or <br />structures on any lot or parcel of ground projected on a hori- <br />zontal plane, excluding permitted projections as allowed by <br />this code. <br />OFFSET. A combination of fittings that crakes two changes <br />In direction, bringing one section of the pipe out of line and <br />into a line parallel with the other section. <br />ON-SITE NONPOTABLE WATER REUSE SYSTEMS. <br />Water systems for the collection, treatment, storage, distribu- <br />tion, and reuse of nonpotable water generated on site, includ- <br />20 2015 INTERNATIONAL RESIDENTIAL CODE* <br />C.opyriEhtq=aIa ICC_ ALL RIG1iT5 RESERVED. Accreacd hY MisBad Flory on Mar 4,20145 a:3954 PM pursuant 10 11xnse Agreemrnt with [CC No further rejaaductlunm <br />diatrihud" aulhariml. ANY UNAUI-HOR120) REPRODUMON OR DISTRIBUMON IS A V101.ATION OF THE FWERALCOPYRIGHT ACT ANDTHE 110ENSE <br />AC.RIT,W-KT,ANOSIIBJRC TOCN1LANDC-RUMINALPENALTIESTHF.REUNDF"i. <br />