My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Vantage Bay PUD Final Development Plan Index Master File
>
Meetings
>
2019
>
09. September
>
2019-09-17 10:00 AM - Commissioners' Agenda
>
Vantage Bay PUD Final Development Plan Index Master File
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2019 12:47:55 PM
Creation date
9/12/2019 12:41:27 PM
Metadata
Fields
Template:
Meeting
Date
9/17/2019
Meeting title
Commissioners' Agenda
Location
Commissioners' Auditorium
Address
205 West 5th Room 109 - Ellensburg
Meeting type
Regular
Meeting document type
Supporting documentation
Supplemental fields
Alpha Order
a
Item
Closed Record Hearing to Consider the Vantage Bay PUD Rezone Final Development Plan (RZ-06-00025)
Order
1
Placement
Board Discussion and Decision
Row ID
56434
Type
Conduct closed record hearing
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
411
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Scope of Supply <br />Project: Vantage Washington WWTP 11-05-17 <br />Plant:MBR 300-2 <br />Quote: 10467-O <br />Dimensions of each module: 1620 mm (L) x 810 mm (W) x 2100 mm (H) <br />Two (2) Mixer, submersible, ABS or equal <br />Permeate Collection Zone <br />Three (3) Permeate pump w/ check valve, isolation valves, and VFD. Goulds centrifugal pump <br />One (1) Permeate flow meter <br />Six (6) Pressure gauge <br />Two (2) TMP pressure transmitter <br />Two (2) Air release valve <br />Air Supply System <br />One (1) EQ/Sludge blower <br />Aersen air blower with VFD, enclosure, check valve, and isolation valve <br />105 cfm at 5.5 psi, GM 3S DN 50, 5HP <br />One (1) Control valve with modulating actuator for EQ tank <br />One (1) Aerobic blower <br />Aersen air blower with VFD, enclosure, check valve, and isolation valve <br />130 cfm at 5.5 psi, GM 4S DN 80, 7.5HP <br />One (1) MBR blower <br />Aersen air blower with VFD, enclosure, check valve, and isolation valve <br />270 cfm at 5.5 psi, GM 7L DN 80, 15HP <br />One (1) Common standby blower <br />Aersen air blower with VFD, enclosure, check valve, and isolation valve <br />270 cfm at 5.5 psi, GM 7L DN 80, 15HP <br />Six (6) Air flow meter <br />Two (2) Air flow sensor <br />CIP system <br />Two (2) Chemcial dosing pumps <br />One (1) Chemical tank w/ level switches <br />UV Disinfection <br />Five (5) UV units, closed vessel, UV Pure Hallett 30 <br />Sludge Holding Zone <br />One (1) Sludge holding tank, constructed of marine grade Aluminum alloy 5086 <br />Dimensions of Tank: 14 ft (L) x 12 ft (W) x 11.5 ft (H) <br />One (1) Sump tank, plastic, Barr <br />TM <br />Two (2) Sump pump, Barnes, submersible, w/ check valves, and isolation vavles <br />Index #6
The URL can be used to link to this page
Your browser does not support the video tag.