Laserfiche WebLink
Printed:6/27|2016 2:53:39 PM Q-2260-16.sbs Page 6 of 9 <br />Section 2 -Products and Fabrication Continued.,. <br />2.02 Rooling and Siding <br />Roof Panels: <br />SuperLok <br />SuperLok shall be roll-formed 16.0"wide with a 2.0"deep straight rib at each edge.One edge rib shall have a "male"flange at its top and the other edge rib shallhavea"female"flange.This design allows a friction interlock of "male/female"ribs on adjacent panels.At end laps the end of the overlapping panel shall be factoryswagedtoallownestingwiththebottompanel. <br />Interlocking straight ribs at side laps shall be field criniped togetlier by the use of an elec1rie seaming tool ob1ained from Star Building Systems.Factory applied <br />scalant shall be provided in the overlapping "female"Bunge to assure weathertightness of the continuously crimped joint.Concealed clips,which are crimped into thepanelsidelaps,shall be famished by Ceco to fasten pancis to structural members. <br />Each panel shall provide 16.0"coverage.Panel gauge is 24 standard with 26 and 22 gauge as an option.Surface texture of panel may be specified as smooth or <br />embossed.Finish may be specified as either Galvalume Plus or painted.Refer to color charts for Standard and Premium paint colors available. <br />*Note -Underwriters Laboratories Approval:SuperLok panels carry a Class 4 UL-2218 rating under impact resistance,Class A UL-263 fire rating,and <br />Class 90 UL-580 uplift resistance rating. <br />*Note -Factory Mutual Approval:SuperLok panels carry a Class 1-SH ilail damage rating,Class A ASTM E108 fire rating,and Class 1-90 FM windstormrating. <br />Wall Panels; <br />Roof Panel Finishes: <br />Manufacturer's standard 0.5 oz.per sq.ft Galvalume Plus alloy-coating with manufacturer's standard polyester finish. <br />Wall Panel Finishes: <br />Manufacturer's standard 0.5 oz.per sq.It galvalume plus alloy-coating (0.55 oz.per sq.ft.unpainted)with manufacturer's standard color siliconized polyester finish. <br />Fasteners <br />Wall Panels: <br />Manufacturer's standard long-life coated #12-x 14 x 0.875"self-drilling carbon steel screws for liner panels and/or exterior single skin wall panels and #12-14 x 1.25"self-drilling carbon steel screws for exterior single skin wall panels utilizing blanket insulation up to 4.0"thick.Manufacturer's standard #14 x 1.75"stainless steelself-tapping screws for factory insulated panels.All exposed fastener heads will be factory colored to match color of panels. <br />Exposed Fasteners for Eave,End Splice,Ridge Cover and Flashings:Manufacture/s standard #12-14 x 1.25"self-drilling screw with sealing washer.Cap head and <br />washer with 0.008"thick type 302 stainless steel caps or zinc/aluminum alloy head.Painted or unpainted. <br />Trim Fasteners: <br />Manufacturer's standard plated and finish painted #8 x 0.625"self-drilling screws with 0.25"hex washer head. <br />Sealant: <br />N/A <br />2.03 Wind Bracing <br />Commercial Grade steel rod bracing,zine coated steel wire strand or portal frames located as determined by Manufacturer on the finalshop drawings. <br />Steel Rod Bracing:Provide complete with necessary slope washers,flat washers and adjusting nuts at each end.Wire Strand Bracing:Provide complete with necessary hardware. <br />All bracing components except wire strand to receive one shop coat of paint. <br />2.04 Wall and Roof Insuladen <br />Wall and Roof Fiberglass insulation <br />Manufacturer's standard noncombustible fiberglass blanket insulation with vapor retarder.Unless shown otherwise on drawings the following Thickness and R Factorswillbeused. <br />En11ding Elevadon Facine Thickneas R ValueN/A <br />Provide insulation and facing (as a composite material )carrying UL fire hazard (UL 723)rating indicating a flame spread rating of 25 or less;or FM classification as <br />Class 1 material when rating is applied to each individual component if field assembled,or to composite unit if supplied factory assembled. <br />2.05 Accessories <br />Gutters <br />N/A <br />Dmynspouts <br />Downspouts shall be located according to design requirements as specified. <br />Downspouts siml]be field attacited to the gutter.Downspouts shall be attaclied to die wall panel using 26-gauge pre-galvartized factory-colored steel straps on 10.0" <br />centers.A 75-degree elbow sha11 f>e provided al the base of all downspoltts to direct the water flow away from the budding wllere required. <br />Finish:Manufacturer's standard siliconized polyester system finish or ful170 percent polyvinylidene fluoride (Kynar)finish in color.