Loading...
HomeMy WebLinkAboutCOP78 MRW North Wall Structural Revision P.O. BOX 926 / 103 EAST 4TH AVE, SUITE 209 ELLENSBURG, WA 98926 509-925-9747 FAX: 509-962-3031 brandon@belsmith.com Sept 9,2026 Re: MRW North Wall Structural Revision Per the description below, we present the following change order proposal #78 (COP#78). COP #78 includes all the labor and materials needed to construct the additional structural needs for the northern wall of the MRW Facility. The items included in this proposal are as shown below. • Box Beam and Wall Attachments • All Columns and Wall Attachments A more detailed cost breakdown is shown below along with the plans that we will be building off. If you have any additional questions, please feel free to reach out. Total cost added to contract: $10,519.29+WSST Time extension required: 87 Calander Days. These additional days extend the contract completion date from the current final contract day of July 14th to October 9th. If the required materials are ordered by Monday, September 14th, they are anticipated to be received by September 24th. Following receipt of the materials, approximately two additional weeks of labor will be required to complete the remaining work. The remaining work consists of fabrication and installation of the box beam and columns, as well as installation of the remaining metal siding. Sincerely, Riley Eres, Belsaas & Smith Construction BELSAAS & SMITH CONSTRUCTION SHEET 1 of 2 C.O.P. #78 CHANGE ORDER PROPOSAL BREAKDOWN SHEET UNIT COSTS EQUIP SUB MATERIAL LABOR #DESCRIPTION QUAN.UNIT Mat.EQUIP LABOR COST COST COST COST MRW North Wall Materials CWallA Steel Framing 1 LS 2484.11 SeaCon Labor Carpenter (2EA - 3 Days)60 HR 93.99 5,639 Office 4 HR 88.00 352 0 Equipment Boom Lift 2 Weeks 3 DAY 250.00 750.00 *TOTALS 750 0.00 2,484 5,991 BELSAAS & SMITH CONSTRUCTION SHEET 2 of 2 C.O.P. #78 CHANGE ORDER PROPOSAL BREAKDOWN SHEET EQUIP SUB MATERIAL LABOR COST COST COST COST TOTALS FROM PREVIOUS PAGE 750.00 0.00 2,484 5,991.40 OVERHEAD 3%22.50 0.00 74.52 179.74 PROFIT 10%77.25 0.00 255.86 617.11 BONDING 1.5%12.75 0.00 42.22 101.82 SUB TOTAL 772.50 0.00 2,857 6,890.08 SUB TOTAL 773 0.00 2,856.71 6,890 LABOR 6,890 MATERIAL 2,856.71 EQUIPMENT 773 SUBCONTRACTORS 0.00 SUB TOTAL SUB TOTAL 10,519.29 GRAND TOTAL TOTAL 10,519.29 TIME EXTENTION REQUIRED:0 NOTICE TO PROCEED REQUIRED BY: WE RESERVE OUR RIGHTS UNDER THE CONTRACT TO ACCESS THIS CHANGE CUMULATIVELY AS IT AFFECTS TIME AND AMOUNT. Project www.lundopsahl.com |Tel: 206.402.5156 Project No. Subject / Reference Client Date Designer 1215 Fourth Avenue, Suite 1200 Seattle, Washington 98161 206-402-5156 |www.lundopsahl.com Kittitas County Transfer Station MRW Building - Adding Exterior Wall w/ Midway Support SCS Engineers AC 22-186-01 9/2/26 1.4 2.4 3.4 4.4 5.4 F.4 E.4 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20 ' - 0 " 7 4_S302 12 4_S302 TYP AT COL 6 4_S302 6.4 4_S302 3 TYP UNO 5'-0" x 5'-0" x 18" D CONC FTG, w/ (7) #5, EA WAY BOT, TYP UNO 7 4_S302 7 4_S302 6 4_S302 SIM BLIND SUMP PER MEP SEE S-SK-07 A PARTIAL PLAN - MRW BUILDING FOUNDATION PLAN SCALE: NTS B EXTERIOR WALL CFS FRAMING CONNECTION TO (E) PEMB COL SCALE: 1 1/2" = 1'-0" B (E) PEMB COL BACK-TO-BACK HORIZ TRACK PER A 400S150-33 BLOCKING @ EA (E) PEMB COL BACK-TO-BACK 400T150-33 @ 24" OC, TYP (2) #8 SCREWS, TYP BLKG TO HORIZ TRACK CONNECTION (3) SELF TAPPING #12 SCREWS, TYP HORIZ TRACK END TO (E) PEMB COL CONNECTION 5/8"ø TITEN HD SCREW ANCHOR @ 48" OC w/ 4" MIN EMBEDMENT T.O.E. CONCRETE (E) CONC FOOTING AND CURB S-SK-11.R1A ( 2 ) 4 0 0 S 3 5 0 - 6 8 B O X E D C O L U M N , T Y P BOXED (2) 600S350-54 @ TOP 0" S-SK-11.R1A C S-SK-11.R1B TOP BOXED BEAM PER A/S-SK-11.R1A, COPE END AROUND (E) PEMB COL BENT PL 3" x 2" x 33MIL x 0"-6" T&B w/ (3) #12 SCREWS INTO (E) PEMB (4) #8 SCREWS, T&B Project www.lundopsahl.com |Tel: 206.402.5156 Project No. Subject / Reference Client Date Designer 1215 Fourth Avenue, Suite 1200 Seattle, Washington 98161 206-402-5156 |www.lundopsahl.com Kittitas County Transfer Station MRW Building - Adding Exterior Wall w/ Midway Support SCS Engineers AC 22-186-01 9/2/26 B EXTERIOR WALL CFS FRAMING CONNECTION TO (E) PEMB COL SCALE: 1 1/2" = 1'-0" S-SK-11.R1B T.O.E. CONCRETE (E) CONC FOOTING AND CURB BACK-TO-BACK HORIZ TRACK PER A/S-SK-11.R1A TYP MIDWAY SUPPORT BOXED COLUMN PER A/S-SK-11.R1A X X X X X X TOP BOXED BEAM PER A/S-SK-11.R1A BENT PL 2" x 2" x 33MIL x 0"-3 1/2" T&B w/ (3) #8 SCREWS INTO COL & BEAM, EA SIDE OF COL X X X BENT PL 2" x 2" x 33MIL x 0"-3 1/2" T&B w/ (3) #8 SCREWS INTO COL & 5/8"ø TITEN HD SCREW ANCHOR w/ 4" MIN EMBEDMENT, EA SIDE OF COL X X X