HomeMy WebLinkAboutI - Fully ExecutedA$,r*,
PAGE 1 of 18
$5,100,000.00.
$0.00
We bring our clients'stores to life
SPOKANE
203 N Woshington
Suite 400
Spokone. WA
992A1
p 509.838,8568
olscorch itecis. com
Amount
$9,211.93
$1,182.24
$12,517.81
$24,059.39
$7,208.00
Total This Change Order: $54,179.37
Accepted
CHANGE ORDER NO. 1
PROJECT NAME
O\A/NER:
CONTRACTOR:
PROJECT NO:
Ellensburg Rodeo Arena Completion
Kittitas County
Cascade Central Construction
2025-009
DESCRIPTION OF CHANGE:
COP 1 -Temporary Fiber
COP 2 - Existing RV Oultet Jbox
COP 3 - Buckaroo Grandstand Receptacles
COP 5 - Buckaroo Press Box Panel
COP 6 - Megaphone Removal
Original Contract Sum
Net Amount of Previously Approved Changes:
Contract Sum Prior to This Change Order:
Contract Sum is increased by This Change Order:
Revised Contract Sum:
Original Contract Completion Date:
Previously Approved lncreases in Time:
Completion Date Prior to This Change Order:
Contract time will be chanqed by 3
Calendar Days This Change Order
Revised Substantial Completion Date:
Revised Final Acceptance Date:
lA^- t---.--),.,J-
$s 100,000.00 By:
$54,179.37
$5,1 54,179.37
7t2012026
KC Carroll
Date 12111125
Recommended By:
ALSC Architects, P.S.
0
By:
Date z ll L5 1
7t2012026
7t23t2026 By: CO r V) rl b ViceClvar
8t2212026 Date tzlta lhs
*Does not include State or Local Sales Tax ALSC Architects I We bring our clients' stories to life.
@
P.O. Box 119
Wenatchee, WA. 98807-0119
Phone 509-662-71 1 I
Fax 509-662-6380
To:
Kittitas Cou nty Com issioners
205 West 5th Ave, Suite 108
Ellensburg, WA 98926
MAKE CHECKS PAYABLE TO:
Cascade Central Construction, LLC
P.O Box 119
Wenatchee, WA. 98807-0119
PROPOSAL
PROJECT: Ellensburg Rodeo Arena lmprovements
coP# 1
DATE: November21,2025
TITLE: Temporary Fiber
CASCADE
CENTRAL
11t21t2025
1112112025
O.b
Sales lax llate.
Schedule lmpact:
One (1) Working Day - New Substantial Compeltion:7121126
General Contractor - Sub Total with 15% Mark-up
Carpenter
Laborer
Project Engineer
Project Management & Coordination
General Conditions
Supervision
Cascade Central Construction Cost
Subcontractor - Sub Total with 6% Mark-up
Electrical Subcontractor - See attached Back-up
Subcontractor Cost
GSCRPnOil
0
0
0
2
1
4
1
c|rAirnnl
HR
HR
HR
HR
WD
HR
LS
tm
TOTAL
8.60%
SUBTOTAL
$1 19.00
$63.08
s 116.25
$161.54
$925.00
$l2AlA
$6,092.00
tn\trfFRrc€
$9.2{ {.93
729.49
a.442.44
2,O24.92
$0.00
$0.00
$0.00
$323.08
$925.00
$512.72
6.457.52
$0.00
$0.00
$0.00
$6,092.00
AIfOITTT
THANKYOU FOR YOUR BUS,,VESS'
McGann Electric
Project Name:
Project No.
Contractor:
Description:
Ellensburg Rodeo Arena lmprovements
CRAFT LABOR COSTS
Direct Labor Costs:
a. crew (apprentices, journeymen, & laboreE)
b. foreman
c. superintendent
Contractor Breakdown Summary
Date:
Contractor Ref. No.
coP-1
l.CRAFTLABORCOSTS $ 1,491.00
2. MATERIAL COSTS $ 1,083.00
3. EQUIPMENT COSTS $
4. SMALL TOOLS 75.00
SUBTOTAL 1 thru 4 $ 2,649.00
5. OVERHEAD & PROFIT $ 424.00
6. SUB-SUBCONTRACTORS $ 2,610.00
392.00
Source Documents:Wyatt Haller 11t't912025
Mccann Electric
Provided and installed temporary plastic handhole at new construction entrance where we intercepted existing fiber from
armory and pulled back and routed under handhole and surface mounted fiber cable to south perimeter fence where we
utililzed exsitng fiber nema3r Jbox and splice enclosure we removed from demoed grandstands. Routed existing fiber from
teanaway/umtaneum hall to splice Jbox and re-spliced on 1 1/5 with data sub (lTG). Tested work completed and WlFl
connection conlirmed. The fiberfrom the second splice box on the southem woodpole that fed east underground to the other
fiber splice box to the south of goldbuckle club would not reach to the southem fence sPlice box of teanaway hall. Provided and
installed new temp single mode 6 strand fiber from Teanaway hall to main grandstand nelwork switch. Surface mounted temp
fiber along fence line along grandstands then utilized existing conduit up to znd floor storage room with netvvork switch.
Terminated both fiber ends and reset both owner network switches on 1 1/1 2. Tested all work completed and confirmed Wl-Fl
connection with facilities manager. The fiber run coiled by south video board that runs to the splice box by gold buckle will
need to be refed along with the fiber cable that fed the south video board from the Buckaroo network switch.
Itemizs ell costs on attached COP Cost BGakdown form.
$
$ 1 ,461.68
$
$ 1,082.99
$
$
74.55
$423.84
$
$ 1 ,1 15.68
$ 1,494.00
Supervision:
d. directsupervision (NTE 15% of la)
e. safety (NTE 2% of lines 1a, b, & c)
2. MATERIAL COSTS
material costs
freight costs (itemize)
3. EOUIPMENT COSTS
a. owned equipment (per spec approved source)
b. rental equipment (per invoices attached)
4. SMALLTOOLS
a. small tools (NTE 5% of 1a & b)
5. OVERHEAD & PROFIT
NTE 1 5% portion ot 1,2,3, & 4 up to $50,000
6. SUB-SUBCONTRACTORS
ITG -fll5
tTG - 11t12
7. OVERHEAD & PROFIT ON SUB-SUBCONTRACTORS
a. NTE I 5% of Line 6 up to $50,000 for each sub
8. INSURANCE
a. payroll driven liability insurance
b. volume driven liability insurance
DIRECT LABOR SUBTOTAL $ 1,461.68
29.23$
a.
b.
$
a,
b.
a.
b.
c-
d.
391.50
$
7. OVERHEAD & PROFIT ON SUB-SUBCONTMCTORS $
0.15 % of 1
0"25 Yool 1-7 $
2.24
15.19 8. INSURANCE S 17.42
9. BOND
a. bond 0.03 % of 1{9. BOND $
Form Revised 04/25115 TOTAL
lmprovemenis COP-'1 Temp Fiber Summary lssued1lnol2o2s
$ 6,092.00
Cost Breakdown
Project Name: Ellensburg Rodeo Arena lmprovments
Project No.
Gontractor: McGannElectric
coP-1
Date:
Contractor Ref. No.
11t19t2025
Description Quantity
Unit
Type
Labor Material Equipment Total
CostUnit $Cost Unit $Cost Unit $Cost
$$$
$$$$
Electrician Labor 6 HR $106.95 $ 641.70 $$$ 641.70
Foreman Labor 7 HR $117.14 $ 819.98 $$$ 819.98
$$$$
$$$$
Plastic Handhole 1 EA $$100.02 $ 100.02 $$ 100.02
Fiber Optic Cable 1 LT $$972.97 $ 972.97 $$ 972.97
1 LT $$10.00 $ 10.00 $$10.00
$$$$
$$$$
$$$$
$$$$
$$$$
$$$$
$$$$
$$$$
$$$$
$$$s
$$$D
$$$$
$$$$
$$$$
$$$$
$$$$
$$$$
Labor Subtotal $ 1.461.68
$$$$
$$$$
$$$$
Subtotal Cost of Work 211t2017 $ 1,46'1.68 $ 1,0E2.99 $$ 2,5M.67
COPW Rates
Project Name: Ellensburg Rodeo Arena lmprov
Project No: ERAI
Contractor:McGenn Electric
NOTES: . Rate schedule date is the date of the Dept. of Labor & lndustries Prevailing Wage Rate used or the Union Agreement.
a. for items 3 thru 5, the Federal rates do not vary by firm, and the percentages are already locked into this form.
b.foritem6,iheactual rateisdeterminedbytheStateEmploymentSecurityDept.andvariesbyfirm. ltshall beverifiedbythecontractorattheslartoftheproiect.
c. for item 7, the rate is based on L & I classification. The hourly dollar amount is specific to the firm/trade and shall be verified by the contractor at the start of the project.
d. definitions
f . items 1 & 2 are basic wages and benefits (see general conditions 7 .OZ B'7 'a(1))
2. item 3, FUI is Federal Unemployment Tax Act (see general conditions 7.02 8.7.a(3))
3. item 4, FICA is Federal lnsurance Compensation Acvsocial Security (see general conditions 7.028.7(3))
4. item 5, Medicare is FICA medical aid (see general conditions 7 .o2 8.7 .a(3\)
5. item 6, SUI is State Unemployment Compensation Act (see general conditions 7.02 8.7.a(3))
6. item 7, WC is industrial insurance/workers' compensation (see general conditions 7.02 8.7.a(21)
7. item 8, AD is additional compensation for education, dental, vision, entertainment, vehicles
Trade &
Position
ELECTRICIAN
JOURNEYMAN
ELECTRICIAN
FOREMAN
ELECTRICIAN
SUPERINTENOENT
Rate Schedule Date*10t25t25 10125125 10125125
3 88.34 J 97.17 3 106.00
1. Hourlv Waoe Rate s 88.34 $ 97.17 $'106.00
SIIETOTAL $ 88.34 t 97 -'17 s 106.00 s $$s $$3
Rate
3 FlJl o/o of 1 0.80%o.71 $0.78 $0.85 $$$$$$$
4 FICA o/o ol 1 6.20%$5.48 $6.02 $6.57 $$$$$$$
o/o of 1 'l AEo/"$'1.28 $1.41 a 1.54 $$$s $$$
6- Sl-Jl % of 1 (insert correct % to riqhl)4.80o/o $4.24 $4.66 $5.09 $$$$$$$
7. WC (insert $ amount per hour)a.95o/n $1.80 $1.85 $'1.90
8.lRA retirement So/o $4.63 $4.75 $5.09
9. WPFM leave 0.50%$0.47 $0.49 $0.51
ToTAL aincl- D.vroll taxesl $ 106.95 s 117.14 s 127.55 $t g $$$$
r - trri<
qI
id.,*i'€:w
6s15 sia\to Lo6",t
a
"J4til ;F
:l
tt
I
I
I
I
\pir.if
F,'br ou+ +o virl" bo^"'l
t'
'AI
,: ]i;iiil
ii l
il i
aH'r
il
.t
I
I
1
1
l
t
f-r;sli^j f;[.r- op+ic {Yr.rP
ALsE,
@
A\mw\v EtgheeJs
ELLENSBURG
RODEOARENA
SEATINO
KITTITAS
COUNTY
BID SET
AITS OEMO FW
ETECTRICAI
E-100
*_T_T-
ffi
ff+-ffi
A
't1.f
n"
flo
tffi--l@
u ileo
-I
r-6i@ \
ou
"Hg*tF{ilii:
;d-'F
,t :q. .
:i?
''r *F ;,
I
E
1t
116F
I
r
I Nee'\ -\o--b-q
r.c4'I /
- ut).el Eoac o\
i-
x
..f(9,clrc bt^rA oe-\s toi'-'\
// lauro
il
,!
e-
l\F fer D.r- O o.na\ T'ernp Fib*r r-s6 fcota Teonowoty *7 9Yrqi6 (:ra'1o\st'n-\
A\L:S"
A\mwvEiqj{9ff.&
ELLENSBURG
RODEOARENA
SEATING
KITTITAS
COUNTY
@
+r_T-
ffi
--l-.{-ffi---l--F-
BID 8ET
o
SITE DEMO PUN
ELECTRICAL
E-100
G
P.O. Box 119
Wenatchee, WA. 98807{111 9
Fax 509-662-d180
o:
Kiftitas County Comissioners
West Sth Ave, Suite 108
Ellensburg, WA 98926
MAKE CHECKS PAYABLE TO:
Cascade Centnl Construction, LLC
P.O Box l19
Wenatchee, WA 98807-01'19
THANK YOU FOR YOUR AUS/iVESSI
PROPOSAL
PROJECT: Ellensburg Rodeo Arena lmprovements
coPrl 2
DATE: November 21, 2025
TITLE: RFI 002 - Existing RV Outlet Jbor
CASCAIIE
CENTRAL
11t21t2025
11t21t2925
h
Schedule lmpact:
GeneEl Contnctor - Sub Total with 15% Mark{p
Carpenter
Laborer
Project Engineer
Proiecl Management & Coordination
General Conditions
Superuision
Cascade Central Construction Cost
Subcontnctor - Sub Total with 6% Mark{p
Electri€l Sub@ntraclor - See attached back-up
Subcontnctor Cost
DESCRFTFil
0
0
0
0
0
0
4rAtfnw
HR
HR
HR
HR
WD
HR
LS
til
Pav This Ahount
Tobl
8.600/"
SUBTOTAL
$1 19.00
$63-Oa
$116.25
$'161.54
$925.00
$124.14
1,O27.00
tsrrpfucE
31-1a2-24
s1.142.21
93.62
1.088.62
0.00
s0.00
$0.00
s0.00
$0.00
$0.00
s0.00
1.088.62
$0.00
$o.oo
s0.00
$1,027.00
lrougt
McGann Electric
Contractor Breakdown Summary
Project Name: Ellensburg Rodeo Arena lmprovements RFI 002 Existing RV Outlet Box coP-2
Project No.
Contractor: McGannElectrlc
Source Documents:Jack Mccann Date: 1111912025
Contractor Ref. No.
Description Remove and dispose damaged Nema 3R Jbox. Provide and install new 12x12x6 Nema 3R Jbox with screw on cover.
Provide and install new bell box covers, pvc fiftings, strut, hardware and terminations. Test all work completed. Clean area
of all constrcution debris. Exclusions: cut patch, paint.
1. CRAFTLABORCOSTS
Direct Labor Costs:
a. crew (apprentices, journeymen, & laborers)
b. foreman
c. superintendent
Item'rze all costs on attached COP Cost Breakdoryn form.
$534.75
DIRECTLABORSUBTOTAL $534.75
Supervision:
d. direct supervision (NTE 15% of 1a)
e. safety (NTE 2% of lines la, b, & c)
I. CRAFT LABORCOSTS $545.00
$
$
$10.70
2. MATERIAL COSTS
a. material costs
b. freight costs (itemize)
3. EQUIPMENTCOSTS
a. owned equipment (per spec approved source)
b. rental equipment (per invoices attached)
4. SMALLTOOLS
a. small tools (NTE 5% of la & b)
5. OVERHEAD&PROFIT
NTE 15% portion of 1,2,3, & 4 up to $50,000
7. OVERHEAD & PROFIT ON SUB-SUBCONTRACTORS
a. NTE 15% of Line 6 up to $50,000 for each sub
s 311.47
2. MATERIALCOSTS $31 1.00
$
3. EQUIPMENT COSTS $
$27.25
4. SMALL TOOLS 27.00
SUBTOTAL 1 thru
$141.28
s
5. OVERHEAD & PROFIT $'141.00
6.SUB.SUBCONTRACTORS $
b
$
7. OVERHEAD & PROFIT ON SUBSUBCONTRACTORS $
$0.82
$2.56 8. INSURANCE $J.JO
9. BOND $
TOTAL COST $ 1,027 00
a.
b.
6. SUB.SUBCONTRACTORS
D
a.
b.
c.
d.
8. INSURANCE
a. payroll driven liability insurance
b. volume driven liability insurance
9. BOND
a. bond
Form Revised 04,2511 5
0.15 % of 1
0.25 olo ot 1'7
0.03 % of 1-g
https://mcgannelectric-my.sharepoint.com/personal/jackmcgann_mcgannelectric_com/Documents/McGann Electric/2025 Ellensburg Rodeo 9.30/COPs/RFl 002 RV
Jbox/Ellensburg Rodeo Arena COP-2 Summary lssued 1 1/2012025
883.00$
Cost Breakdown
Project Name: Ellensburg Rodeo Arena lmprovments
Project No.
Contractor: McGannElectric
coP-2
Date:
Contractor Ref. No.
11t19t2025
Description Quantitv
Unit
Tvpe
Labor Material Equipment Total
CostUnit $Cost Unit $Cost Unit $Cost
$$$$
$$$$
Electrician Labor 5 HR $106.95 $ 534.75 $$$ 534.75
Foreman Labor HR $117.14 $$$$
$$$$
$$$$
$$$$
12x12x6 Nema3R Jbox 1 EA $$144.74 $ 144,74 $$ 144.74
Sinole qanq WP cover 2 EA $$17.94 $35.88 $$35.88
Shallow strut 10 FT $$2.43 $ 24.30 $$24.30
2" pvc fttinqs 1 LT $$4.62 s 4.62 $$4.62
1.25" pvc fittings 1 LT $$2.41 $2.41 $$2.41
1" pvc fittinqs I LT $$10.06 $10.06 $$10_06
qround luq 1 EA $$3.03 $3.03 $$3.03
hardware I LT $$15.50 s 15.50 $$15.50
terminations - WP 1 LT $$70.93 $ 70.93 $$70.93
$$$
$$$$
$$$$
$$$$
$$$
$$$$
s $$
$$$$
$$$$
$$$$
Labor Subtotal 534.75
$$$$
$$$
$$$$
Subtotal Cost of Work 2t112017 $ 534.75 $ 3'11.47 $$ 846.22
lssued 1 l/20/2025
G
P.O. Box l19
Wenatchee, WA. 98807-01 19
Phone 509-662-7119
Far 509{62-5380
To:
Kittitas County Comissioners
205 West Sth Ave, Suite 108
Ellensburg, WA 98926
i,AKE CHECKS PAYABLE TO:
Cascade Central construction, LLC
P.O Box 119
Wenatchee, WA. 98807-01 19
PROPOSAL
PROJECT: Ellensburg Rodeo Arena lmprovements
COP# 3
DATE: Novembet21,2025
TITLE: RFI 003 - Buckaroo Grandstand Receptacles
CASCADE
CEI{TRAL
1112112025
1112112025
Tb
Schedule lmpact:
Two (2) Working Days - New Subslantial Completion: 7/23126
General Contractor - Sub Total with 15% Mark-up
Carpenter
Laborer
Projecl Engineer
Project Management & Coordination
General Conditions
Supervision
Cascade Cenual Construction Cost
Subcontractor - Sub Total with 6% Mark-up
Electrical Subcontraclor - See attached Back-up
Subcontractor cost
D€SCBPTIOII
0
0
2
2
2
4
1
qJAIITTY
HR
HR
HR
HR
WD
HR
LS
tofl
Pav This Amount
Total
8.60%
SUBTOTAL
s 119.00
s 53.08
$116.25
$161.54
€925.00
$128.18
$7.708.00
UMTPfUCE
$12.517.81
$12.517.81
991.28
1 1 526.53
3.356.05
$0.00
$0.00
$232.50
$323.08
$'1,850.00
9512.72
8.,t70.48
$0.00
$0.00
$0.00
$7,70E.00
ATOIf,{T
THANK YOU FOR YOUR BUS'IVESS'
McGann Electric
Project Name:
Project No.
Contractor:
Description:
Contractor Breakdown Summary
Mccann Electric
Date:
Contractor Ref. No.
Provide and install 2 - 1" underground ra@ways from PNL - LIA to existing buckaroo grandstand receptacles location.
Provide and install 1 - 5OA 2 pole circuit breaker in PNL - LlA. Utilize exsiting 2 - 20A lpole spare breakers in PNL - L1A for
existing receptacle circuits. Provide and install 1 - 5OA 2pole 2O8v circuit for exsitng 50A receptacle from PNL - 1 LA. Provide
and install 2 -2OA 12Ov circuits for 2 existing receptacle circuits under grandstands. All conduit, fittings, wire, supports,
breakers, hardware and terminations included. Exclusions: cut patch and paint, trenching and backfill.
Itemhatl cosils on athclred COP Cost Bteak(bwn forn.
Ellensburg Rodeo Arena lmprovements RFI 003 Buckaroo Receptacles
Source Documents: Jack Mccann
coP-3
11t20t2025
l.CRAFTLABORCOSTS $ 4,312.00
2. MATERTAL COSTS $ 2,094.00
I. CRAFTLABORCOSTS
Direct Labor Costs:
crew (apprentices, journeymen, & laborers)
foreman
superintendent
a. payroll driven liability insurance
b. volume driven liability insurance
Supervision:
d. direct supervision (NTE 15o/o ot 1al
e. safety (NTE 2% of lines la, b, & c)
2. MATERIALCOSTS
a. material costs
b. freight costs (itemize)
3. EQUIPMENTCOSTS
a. owned equipment (per spec approved source)
b. rental equipment (per invoices attached)
4. SMALLTOOLS
a. small tools (NTE 5% of la & b)
5. OVERHEAD&PROFIT
a. NTE t5% portion of 1,2, 3, & 4 up to $50,000
b.
5. SUB-SUBCONTRACTORS
7. OVERHEAD & PROFIT ON SUB.SUBCONTRACTORS
a. NTE 15% of Line 6 up to $50,000 for each sub
8. INSURANCE
$ 4,227.'t4
DIRECT LABOR SUBTOTAL $ 4,227.14
$u.54
$ 2,094.26
a.
b.
c.
$
$
3. EQUIPMENT COSTS $
215.60
4. SMALLTOOLS $216.00
SUBTOTAL I thru
$ 1,059.52
$
5. OVERHEAD & PROFIT $ 1,060.00
6.SUB-SUBCONTRACTORS $
$
7. OVERHEAD & PROFIT ON SUB.SUBCONTRACTORS $
$6.47
$19.21 8. INSURANCE $25.67
a,
b.
c.
d.
O.15 o/o of 1
0.25 o/o ol 1-7
9. BOND
a. bond 0.03 % of 'l-8 9. BOND $
TOTAL COST $7.708.00
https://mcgannelectric-my.sharepoint.com/peBonal4ackmcgann_mcgannelectric_com/Documents/McGann Electric/z025 Ellensburg Rodeo 9.30/COPs/RFl 3 Grandstand
Receptacles/Ellensburg Rodeo Arena lmprovements COP-3 Summary lssued 1112012025
622.00
Cost Breakdown
Project Name: Ellensburg Rodeo Arena lmprovments RFI 003
Project No.
Contractor: McGannElectric
coP-3
Date:
Contractor Ref. No.
11t20t2025
Description Quantity
Unit
Tvpe
Labor Material Equipment Total
CostUnit $Cost Unit $Cost Unit $Cost
$$$$
$$$$
Electrician Labor 22 HR $106.95 $ 2,352.90 $$$ 2,352.90
Foreman Labor 16 HR $117.14 s 1.874.24 $$$ 1,874.24
$$$$
$$$$
50A 2pole QBHW breaker 1 EA $$166.04 $ 166.04 $$ 166.04
1" emt 20 FT $$1.94 $38.80 $$38.80
1" emt connectors 4 EA $$5.89 $ 23.56 $$ 23.56
1" riqid coupling 4 EA $$5.76 $23.04 $$23.04
'1" riqid 90 8 EA $$19.29 $ 154.32 $$ 154.32
't" riqid 40 FT $$6.1 5 $ 246.00 $$ 246.00
1" riqid threadless connector 2 EA $$14.64 $ 29.28 $$ 29.28
1'PVC 280 FT $$0.62 $ 173.60 $$ 173.60
1" PVC couplinqs 12 EA $$0.61 $7.32 $$7.32
1'PVC FA 16 EA $$0.91 $14.56 $$14.56
1'' LB 2 EA $$1 8.1 0 $36.20 $$36.20
deep strut 10 FT $$3.41 $34.1 0 $$34.1 0
1" strut straps 8 EA $$1.68 $'13.44 $$13.44
#6 thhn 540 FT $$1.11 $ 599.40 $$ 599.40
#8 thhn 180 FT $$0.72 $ 129.60 $$ 129.60
#12 thhn 1 500 FT $$0.25 $ 375.00 $$ 375.00
hardware, terminations, glue, tape 1 LT $$30.00 $30.00 $$30.00
$s $$
$$$$
$$$$
Labor Subtotal $ 4.227.',14
$$$$
$$$$
$$$$
Subtotal Cost of Work 21112017 $ 4,227.14 $ 2,094.26 $$ 6,321.40
G CASCADE
CEilTRAL PROPOSAL
P.O. Box 119
Wenatchee, WA. 98807-01 19
Phone 509-662-7119
Fax 509-662-6380
To:
Kittitas County Comissioners
205 West 5th Ave, Suite 108
Ellensburg, WA 98926
MAKE CHECKS PAYABLE TO:
Cascade cenual Construction, LLG
P.O Box 119
Wenatchee, WA. 98807-0'119
PROJECT: Ellensburg Rodeo Arena lmprovements
coP# s
DATE: Decembet10,2025
TITLE: RFI 004 - Buckaroo Press Box Panel
12t10t2025
1211012025
O!t!
Schedule lmpact:
None, work is able to occur in same sequence as contlacl work.
General Contractor - Sub Total with 15% Mark-up
Carpenter
Laborer - Hand Digging and backfill at structure to route conduit
Projeci Engineer
Project Management & Coordination
General Conditions
Superuision
Cascade Central Construction Cost
Subcontractor - Sub Total with 6% Mark-up
Earthwork - Minimal added work, utilize same trench as other pathway, no
added cos{
Electrical Subcontraclor - See attached Back-up
Subcontractor Cost
oEscdPnon
u
8
0
2
0
2
I
4'AI{TITY
HR
HR
HR
HR
WD
HR
LS
r,()r
Total
8.60%
SUBTOTAL
s 1 19.00
$63.08
$116.25
s '161.54
$925.00
$128.18
$19,724.OO
tntrPtilc€
s24.059.39
s24.059-30
1.905.26
22.154.13
1.246.69
$0.00
$504.64
$0.00
$323.08
$0.00
$256.36
20.907.4
$0.00
$0.00
$0.00
$19,724.00
AId'IT
THANKYOU FOR YOUR AUS'A'ESS'
McGann Electric
Project Name:
Project No.
Contractor:
Ellensburg Rodeo Arena lmprovements RFI 004 Buckaroo Panel
source Documents: Jack Mccann
Mccann Electric
Contractor Breakdown Summary
Date: 121512025
Contractor Ref. No.
170.88
143.42
1. CRAFT LABOR COSTS $ 7,314.00
ccc
2. MATERTAL COSTS $ 9,272.00
3. EOUIPMENT COSTS $
4. SMALLTOOLS $366.00
SUBTOTAL 1 thru
5. OVERHEAD & PROFIT
6.SUB-SUBCONTRACTORS $
60.1 3
Description: Demo out existing 2OOA feeder, 2" raceway and 2OOA panel in Buckaroo press box. Provide and install new 2.5" underground
conduit from MDPL to Buckaroo press box panel location. Provide and install 4#3/0's and #4 ground. Provide and install new
3PH, 225A rated 2OBY|12OV 42citcuit recessed bottom fed panel with surge protection. Provide and install new 200A 3pole
breaker in MDPL. Provide and install circuit breakers to match exisitng circuits in press box. Provide nevv grounding and
bonding at panel location. Reconnect all existng branch conduits and circuits to new panel. Remove drywall above and below
panel to make room for panel and conduit connections. Label all circuits in panelboard. Provide and install phenolic labels on
panel and MDPL. All conduit, fittings, wire, panel, breakers, supports, hardware, grounding and terminations included.
Exclusions: patch and paint
CRAFT LABOR COSTS ltemke all co6t9 on ffched COF Gost Brealdosn form.
Direct Labor Costs:
a. crew (apprentices, joumeymen, & laborers)
b. foreman
c. superintendent $
DIRECT LABOR SUBTOTAL $ 7,170.88
$ 9,271.67
$
$
Supervision:
d. direct supervision (NTE 1 5% of I a)
e. safety (NTE 2% of lines la, b, & c)
2. MATERIAL COSTS
a, material costs
b. freight costs (itemize)
3. EQUIPMENTCOSTS
a. owned equipment (per spec approved source)
b. rental equipment (per invoices attached)
4. SMALLTOOLS
a. small tools (NTE 5% of 1a & b)
5. OVERHEAD&PROFIT
a. NTE 15% portion of 1, 2, 3, &4upto$50,000
b.
6. SUB-SUBCONTRACTORS
7. OVERHEAD & PROFIT ON SUB-SUBCONTRACTORS
a. NTE t5% of Line 6 up to $50,000 for each sub
$
$
$
365.70
$ 2,712.32
a.
b.
c.
d.$
8. INSURANCE
a. payroll driven liability insurance
b. volume driven liability insurance
0.15 % of I
0.25 o/" ot 1-7
7. OVERHEAD & PROFIT ON SUB-SUBCONTRACTORS $
10.97
49.16 8. INSURANCE $
$
$
9. BOND
a. bond 0.03 % of l€9. BOND $
Fom Re&d 04t5l15 TOTAL
https://mcganneleclric-my.sharepoint.com/personal4ackmcgann_mcgannelectric_com/Documents/McGann Electric/2025 Ellensburg Rodeo 9.30/COPs/COP4
PnuEllensburg Rodeo Arena lmprovements COP-4 Summary lssued 1218/2025
$ 16.952.00
$19 724.00
Cost Breakdown
Project Name: Ellensburg Rodeo Arena lmprovments RFI 004
Project No.
Contractor: McGannElectric
coP4
1?J512025Date:
Contractor Ref. No.
Description Quantity
Unit
Tvpe
Labor Material Equipment Total
CostUnit $Cost Unit $Cost Unit $Cost
s $$$
$$$$
Electrician Labor 32 HR $106.95 s 3.422.40 $$$ 3,422.40
Foreman Labor 32 HR $117.14 $ 3,748.48 $$s 3.748.48
$$$$
Panel. main and branch breakers 1 LT $$3,970.00 $ 3.970.00 $$ 3.970.00
$$$$
$$$$
2.5" pvc bell end 1 EA $$11.26 $11.26 $11.26
2.5" pvc 160 FT $$2.03 $ 324.80 $$ 324.80
2.5" couplinqs 10 EA $$2.63 $26.30 $$26.30
2.5" riqid 90 4 EA $$91.67 $ 366.68 $$ 366.68
2.5" pvc FA I EA $$3.93 $31.44 $$31.44
2.5" riqid 40 FT $$22.22 $ 888.80 $$ 888.80
2.5" riqid threadless connector 1 EA $$175.25 $ 175.2s $$ 175.25
deep shut 10 Ft $$2.62 $26.20 $$26.20
2.5" riqid strut straps 4 EA $$3.21 $12.84 $$12.84
qroundinq and bondinq 1 LT $$55.00 $55.00 $$55.00
olue. hardware.taoe, ohenolics 1 LT $$75.00 $75.00 $$75.00
2.5" lock rinqs and bushings I LT $$10.00 $10.00 $$10.00
#250A1 920 FT $$1.90 $ 1,748.00 $$ 1.748.00
tJ4 thhn 230 FT $$1.54 $ 354.20 s $ 354.20
$$$$
Lift fees 4x4 scissor larqe working 'l LT $$1,090.00 $ 1,090.00 $$ 1,090.00
Permit fees (added feeder)1 LT $$105.90 $ 105.90 $$ 105.90
Labor Subtotal $ 7,170.88
$s $$
$$$$
$$$$
Subtotal Cost of Work 2t1t2017 $ 7,170.8E $ 9,271.67 $$ 16,442.55
G
P.O. Box 119
Wenatchee, WA. 9E807-{rl l9
Phone 509{62-71{9
Fax 509662-6380
Kittitas County Comissioners
205 West 5th Ave, Suite 108
Ellensburg, WA 98926
MAKE CHECKS PAYABLE TO:
Cascade Central Construction, LLC
P.O Box'119
Wenatchee, WA. 98807-01 19
PROPOSAL
PROJECT: Ellensburg Rodeo Arena lmprovements
coP# 6
DATE: DecembetlO,2025
TITLE: Megaphone Removal
CASCADE
CENTRAL
1211012025
1211012025
Orb
Schedule lmpact:
None
General Contractor - Sub Total with 15% Mark-uo
Carpenter
Laborer
Prciect Engineer
Projeci Management & Coordination
General Conditions
Supervision
Cascade central Construction Cost
Subcontractor - Sub Total with 6% Mark-up
Electrical Subcontraclor - No cost, added work was minimal
Demolition Subcontractor - See attached Back-up
Subcontractor Cost
DESCtrnOil
0
0
0
2
0
0
1
1
auAianTY
HR
HR
HR
HR
WD
HR
LS
LS
toll
Total
8.600/"
SUBTOTAL
$'t '19_00
$63.08
!116.25
$16'1.54
c 925.00
$128.',18
$5,91 1.00
t t$tpREE
37.208.00
$7,208.00
570_80
6.637.20
371.9
$0.00
$0.00
$0.00
$323.08
$0.00
$0.00
6.265.66
$0.00
s0.00
$0.00
$5,91 1.00
AIO|fut
THANK YOU FOR YOUR BUSTA'ESS!
CHANGE ORDER
SafeGuard Abatement
1702 Englewood Ave
Yakima, WA 98902
(so9) 7se-748 I
www.safeguardabatem ent.com
CHANGE ORDER NUMBER:
Customer: Cascade Central (Rusty & KC)
Project: Ellensburg Rodeo
Description of change:
- Remove speakers from center of arena
+ 2 labors I day = 20 hrs
- Boom lift "rental" 1 week charge for electrician
Payment for this change order is payable as follows (due within 7 days of signing below if left blank):
. The original Contract Price was. ' . 'r Net change by previously authorized Change Orders...,
r The Contract Price prior to this Change Order was,....'
This Change Order will
Customer
12t30t2
Date
a
a
a
I increase
E decrease
the Contact Price by
The new Contract Price including this Change Order will be
This Change Order will Iincrease
E decrease
the Contract Time by approx.days.
)2liu i05
Date
1
1
Elite Services, LLC d/b/a Safeguard Abatement
CHANGE ORDER
SafeGuard Abatement
1702 Englewood Ave
Yakima, WA 98902
(s09) 7s9-7481
www. safeguardabatement. com
CHANGE ORDER NUMBER:
Customer: Cascade Central (Rusty & KC)
Project: Ellensburg Rodeo
Description of change:
- Remove speakers from center of arena
+ 2 labors I day:29 1n.
- Boom lift "rental" I week charge for electrician
Payment for this change order is payable as follows (due within 7 days of signing below if left blank)
o The original Contract Price was. . . .
o Net change by previously authorized Change Orders..,
. The Contract Price prior to this Change Order was.....
. This Change Order will I increase
E decrease
the Contract Price by ......
. The new Contract Price including this Change Order will be .
o This Change Order will Iincrease
E] decrease
the Contract Time by approx.days.
)2liu las
Customer Date
.-$+28+Se*f
.. $0.00j,tz*r:0nr
.s'*r.gcl-.-o0--
Eric Pfeifer, Estimator
Elite Environmental Services, LLC dlb I a Safeguard Abatement
Date
t -\,e Qrr,\n.l\L\
\5r\a,hrw
{ fr3c
1
.$5.91 1.00
1
t* 0sl,,ri\ o'hlr