HomeMy WebLinkAbout2018-02-26-minutes-cds-study-sessionKITTITAS COUNTY COMMISSIONERS
CDS Study Session
Regular Meeting
Monday February 26, 2018 -1:30 PM
Commissioners' Auditorium
205 West 5th Room 109 - Ellensburg
1 Call to Order
2. Voluntary Stewardship Program (VSP) Status Update
3. Discussion Regarding Use of Intumescent Finishes
4. Discussion Regarding Wildland Urban Interface Map
5. Other business
6. Adjourn
Created on 2/23/2018 10:09:52 AM
KITTITAS COUNTY COMMUNITY DEVELOPMENT SERVICES
>>lW .HCl
411 N. Ruby St., Suite 2, Ellensburg, WA 98926
CDS@CO.KITTITAS. WA.US
Office (509) 962-7506
"Building Partnerships — Building Communities" Fax (509) 962-7682
Kf1TrrAS COUNTY
CDS STUDY SESSION MINUTES
February 26, 2018 —1:30 PM
THOSE PRESENT: Paul Jewell, Obie O'Brien (BOCC) Dan Carlson, Stephanie Mifflin, Lindsey Ozbolt
Calvana Carper (CDS) Mark Cook, Candie Leader (PW), Clay Myers (Sheriff),
GUESTS PRESENT: Joe Seemiller, John Sinclair (KVFR), Anna Lael (KCCD), Daily Record Reporter
Voluntary Stewardship Prozram WSP) Status Update:
Ms. Lael shared that the watershed group gave approval to submit the work -plan to State Conservation Commission on
March 1, 2018. There will be a 2 week public comment period. Following that period, they will then present their work plan
to the State Technical Panel. Final presentation will be April 27, 2018, Implementation to begin immediately upon approval.
To view drafts and comment matrixes, www.KCCD.net
Board Direction: None.
Discussion Rej?ardin_g Use of Intumescent Finishes:
Mr. Carlson, CDS Director, stated that there have been requests from various Fire Districts urging the County to not allow
field applied intumescent finishes as alternative means for non-combustible building materials as a requirement from WUI
Code. He stated the current practice was result of past Fire Marshal interruption of the WUI Code. Mr. Flory, Building
Official, explained that the WUI stated that fire retardant treated wood shall be label for exterior use and meet requirement in
section 23.032 of the International Building Code. The current building code states that fire retardant treated wood is any
wood product which is impregnated with chemicals via pressured process or other means during manufacturing. The
building code doesn't discuss field applied intumescent paints, stains, or additivities, to help meet non-combustible status or
ignition resistant status. The building code further states that this practice would require additional inspections under chapter
17. Mr. Flory shared that the conditions of these special inspections would be difficult to inspect and meet standards set forth
in the code. Field applied intumescent finishes have the longevity of 2-5 years based on the manufacturer and based on the
conditions. The reapplication process is the critical piece that can't be verified at this point.
Mr. Sinclair stated he recommends that the county move swiftly and not allow this practice to be used moving forward. Mr.
Seemiller stated that he suspected that someone in the past saw the intumescent finishes as an equivalency to fire resistant
materials, which is not the case.
Board Direction: Call a meeting with the Central Washington Homebuilders Association to discuss how this practice will
impact the community moving forward.
Discussion Re,ardin, Wildland Urban Interface Map:
Mr. Carlson recommended that the county take a look at the map and take into account some of the risk factors like
vegetation, irrigation, and population density. Updating the map would balance out the IR -1 rating zones.
Board Direction: Call a meeting with the builder community and hear this input regarding updating the Wildland Urban
Interface Map.
X -4-?
Dan Carlson, Director
X
Paul Jewell, ChaFinan
COMMUNITY PLANNING • BUILDING INSPECTION • PLAN REVIEW • ADMINISTRATION 0 PERMIT SERVICES • CODE ENFORCEMENT
WUIC CODE REQUIREMENTS FOR NON-COMBUSTIBLE MATERIALS
WUIC 504.5 Exterior walls.
Exterior walls of buildings or structures shall be constructed with one of the following methods:
1. Materials approved for not less than 1 -hour fire -resistance -rated construction on the exterior
side.
2. Approved noncombustible materials.
3. Heavy timber or log wall construction.
4. Fire -retardant -treated wood on the exterior side. The fire -retardant -treated wood shall be
labeled for exterior use and meet the requirements of Section 2303.2 of the International
Building Code.
5. Ignition -resistant materials complying with Section 503.2 on the exterior side.
Such material shall extend from the top of the foundation to the underside of the roof
sheathing.
WUIC 503.2 Ignition -resistant building material.
Ignition -resistant building materials shall comply with any one of the following:
1. Material shall be tested on all sides with the extended ASTM E 84 (UL 723) test or
ASTM E 2768, except panel products shall be permitted to test only the front and back
faces. Panel products shall be tested with a ripped or cut longitudinal gap of 1/8
inch (3.2mm).Materials that, when tested in accordance with the test procedures set forth in
ASTM E 84 or UL 723 for a test period of 30 minutes, or with ASTM E 2768, comply with
the following:
1.1. Flame spread. Material shall exhibit a flame spread index not exceeding 25 and
shall not show evidence of progressive combustion following the extended 30 -
minute test.
1.2. Flame front. Material shall exhibit a flame front that does not progress more
than 10 '/ feet (3200 mm) beyond the centerline of the burner at any time
during the extended 30 -minute test.
1.3. Weathering. Ignition -resistant building materials shall maintain their
performance in accordance with this section under conditions of use. Materials
shall meet the performance requirements for weathering (including exposure to
temperature, moisture and ultraviolet radiation) contained in the following
standards, as applicable to the materials and the conditions of use:
1.3.1. Method A "Test Method for Accelerated Weathering of Fire -
Retardant -Treated Wood for Fire Testing" in ASTM D 2898, for fire retardant -
treated wood, wood -plastic composite and plastic lumber
materials.
1.3.2. ASTM D 7032 for wood -plastic composite materials.
1.3.3. ASTM D 6662 for plastic lumber materials.
1.4. Identification. All materials shall bear identification showing the fire test results.
Exception, Materials comprised of a combustible core and a noncombustible
exterior covering, comprised of made from either aluminum at a minimum 0.019 inch
(0.48 mm) thickness or corrosion -resistant steel at a minimum 0.0149 inch (0.38 mm)
thickness shall not be required to be tested with a ripped or out longitudinal gap.
2. Noncombustible material. Material that complies with the requirements for
noncombustible materials in Section 202.
3. fire-retardant4reated wood. Fire -retardant -treated wood identified for exterior use and
meeting the requirements of Section 2303.2 of the International Building Code.
4. Fire -retardant -treated wood roof coverings. Roof assemblies containing fire-retardanttreated
wood shingles and shakes that comply with the requirements of Section 1505.6
of the Intemational Building Code and classified as Class A roof assemblies as required
in Section 1505.2 of the Intemational Building Code.
IBC 2303.2 Fire -retardant -treated wood. Fire -retardant -treated
wood is any wood product which, when impregnated with chemicals by a pressure process or
other means during manufacture, shall have, when tested in accordance with ASTM
E84 or UL 723, a listed flame spread index of 25 or less and show no evidence of significant
progressive combustion when the test is continued for an additional 20 -minute period.
Additionally, the flame front shall not progress more than 101/2 feet (3200 mm) beyond the
centerline of the burners at any time during the test.
2303.2.1 Pressure process. For wood products impregnated with chemicals by a pressure
process, the process shall be performed in closed vessels under pressures not
less than 50 pounds per square inch gauge (psig) (345 kPa).
January 25, 2018
Dan Carlson, Kittitas County Community Development Director
411 N Ruby St
Ellensburg, WA 98926
The Kittitas County Fire Chief s Association has discussed the practice of allowing the use of
intumescent paints and stains as alternatives to fire resistive products such as cement board
siding (Hardieplank), stucco, brick, brick veneer, stone, stone veneer, steel, aluminum and
corrugated metal. We collectively ask that this practice be discontinued for public safety
reasons.
Section 104.9 of the 2015 International Fire Code permits alternative materials and methods
provided, "the material, method or work offered is, for the purpose intended, at least the
equivalent of that prescribed in this code in quality, strength, effectiveness, rrre resistance,
durability and safety." Intumescent finishes are not equivalent to inherently fire resistant
products:
Fire resistant siding retains its fire resistive rating for the life of the siding. Intumescent
products lose their fire resistive properties between 2 to 5 years due to degradation from
ultraviolet radiation, precipitation, pollution and temperature variations.
Verification of the installation of inherently fire resistive products is easy to verify.
Intumescent finishes look like their non -fire resistive counterparts making verification
nearly impossible.
Once a certificate of occupancy is issued, there are no follow up inspections. Re-
application of the correct product, to manufacturer's specifications and on a time
schedule that matches the UV damage timeline (which would be different for every
structure) is necessary to meet the original intent of the code.
Intumescent finishes should not be permitted as an equivalent material for inherently fire
resistive products and this exemption should be removed from the Kittitas County amendments
to the Wildland Urban Interface Code. Thank you for your time and consideration in this matter.
This letter conveys a unanimous request from all members. Additionally, the following agencies
are specifically asking for intumescent finishes to be removed as alternative to non-combustible
siding in their respective fire response jurisdictions: 101 z
KCFQ I — Braf don Schmidt
�Sfeve Jensen' KCFp 3
Tim Milbert — KCFD 6
Sinclao' — KVFR
J y Wiseman — KCFD 7/KCFD 51
William Rose — KCFD 4
CC - Mike Flory — Kittitas County Community Development
Laura Osiadacz — Kittitas County Commissioner
Obie O'Brien — Kittitas County Commissioner
Paul Jewell — Kittitas County Commissioner
r--_.
r
9
-c=
r
9