Fully Executed Change Order
>
Meetings
>
2026
>
06. June
>
2026-06-02 10:00 AM - Commissioners' Agenda
>
Fully Executed Change Order
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2026 11:01:16 AM
Creation date
6/11/2026 10:59:53 AM
Metadata
Fields
Template:
Meeting
Date
6/2/2026
Meeting title
Commissioners' Agenda
Location
Commissioners' Auditorium
Address
205 West 5th Room 109 - Ellensburg
Meeting type
Regular
Meeting document type
Fully Executed Version
Supplemental fields
Item
Request to Approve Change Order #8 for the Ellensburg Rodeo Arena Project
Order
13
Placement
Consent Agenda
Row ID
144971
Type
Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c cAscAllE <br />CENTRAL <br />REQUEST FOR INFORMATION <br />TO: <br />Todd Keller (ALSC Architects) <br />203 North Washinston, Suite 400 <br />Spokane, WA 99201 <br />Date:4t27t2026 RFt 116 <br />Project Ellensburg Rodeo Arena lmprovements <br />1 01 0 East 8th Ave. <br />Ellensburq, WA 98926 <br />Section <br />Division <br />Title PIV Layout Clarification <br />Requested <br />Respond by Date: <br />RFI DESCRIPTION <br />The attached SK-1 '16.1 reflects the layout required by the Fire Marshal, which includes maintaining 3 feet of clear spacing on all sides with <br />bollards due to potential vehicle and trailer traffic. <br />As shown, this configuration occupies approximately half of the sidewalk and with multiple underground utilities, making excavation in this <br />area challenging. <br />A more suitable location would be near the hydrant. Additionally, local code does not require the PIV to be connected to the fire alarm <br />system. Please confirm whether the Plv is required to be tied into the fire alarm system. <br />lf a connection is not required, relocating the PIV near the hydrant would be a more cost-effective solution. lf a connection is required, it <br />would necessitate trenching across the iite again; however, this alternative location would still be more practical from a constructability <br />standpoint. <br />lmpact: Pending response, TBD <br />Reference Sketch:sK-116.1 <br />Reference Sheets ASlOO <br />RESPONSE TO RFI <br />Let us know if moving it to the east if feasible. This would be more out of the way but understand it <br />extends the line. Kady does not want it to be by the fire hydrant as it will be an obstruction for concert <br />events etc. Keeping ii off the track and BTC area is preferred. See notes below for tie in to the fire <br />alarm. <br />Todd Keller ALSC 4128126 <br />RESPONSE BY:DATE: <br />COPY TO :Andrew Leeper (ALSC Architects)SIGNED Carkl Sa6e[ra <br />Cascade Central Construction <br />Project Engineer <br />RESPONSE TO RFI <br />MW Electrical Comment: <br />It is recommended io utilize the fire alarm system to provide supervision of the Post lndicator Valve (PlV). lt is not necessarily required to be <br />tied into the fire alarm system however, per trlFpR 13, Section 16.9.3.3.1 it is required to be supervised to prevent accidental shutoff' <br />Acceptable methods of supervision are identified below: <br />1, Electronically: Monitored by a central station, proprietary, or remote station signaling service. <br />2. Local Alarm: A local signaling service that notifies building occupants of a valve closure. <br />3. Locking: Valves are locked in the open posilion. <br />4. Sealinj': Valves are sealed within fenced enclosures under control ol the owner, with inspections conducted weekly. <br />RESPONSE BY: Aaron Lanegan oATEz 04-28-2026
The URL can be used to link to this page
Your browser does not support the video tag.