My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2026-0206 Cle Elum Transfer Station Project Manual
>
Meetings
>
2026
>
04. April
>
2026-04-07 10:00 AM - Commissioners' Agenda
>
2026-0206 Cle Elum Transfer Station Project Manual
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2026 12:38:37 PM
Creation date
4/2/2026 12:23:36 PM
Metadata
Fields
Template:
Meeting
Date
4/7/2026
Meeting title
Commissioners' Agenda
Location
Commissioners' Auditorium
Address
205 West 5th Room 109 - Ellensburg
Meeting type
Regular
Meeting document type
Supporting documentation
Supplemental fields
Item
Request to Approve an Agreement for Services with Gibson and Son for the New Entrance and Tank Replacement at the Cle Elum Transfer Station
Order
4
Placement
Consent Agenda
Row ID
143218
Type
Agreement
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
365
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FRIEDMAN & BRUYA, INC. <br />_________________________________________________ <br />ENVIRONMENTAL CHEMISTS <br /> 8 <br /> <br />Data Qualifiers & Definitions a - The analyte was detected at a level less than five times the reporting limit. The RPD results may not provide reliable information on the variability of the analysis. <br /> b - The analyte was spiked at a level that was less than five times that present in the sample. Matrix spike recoveries may not be meaningful. <br /> ca - The calibration results for the analyte were outside of acceptance criteria, biased low; or, the calibration results for the analyte were outside of acceptance criteria, biased high, with a detection for the analyte in the sample. The value reported is an estimate. <br /> c - The presence of the analyte may be due to carryover from previous sample injections. <br /> cf - The sample was centrifuged prior to analysis. <br /> d - The sample was diluted. Detection limits were raised and surrogate recoveries may not be meaningful. <br /> dv - Insufficient sample volume was available to achieve normal reporting limits. <br /> f - The sample was laboratory filtered prior to analysis. <br /> fb - The analyte was detected in the method blank. <br /> fc - The analyte is a common laboratory and field contaminant. <br /> hr - The sample and duplicate were reextracted and reanalyzed. RPD results were still outside of control limits. Variability is attributed to sample inhomogeneity. <br /> hs - Headspace was present in the container used for analysis. <br /> ht – The analysis was performed outside the method or client-specified holding time requirement. <br /> ip - Recovery fell outside of control limits due to sample matrix effects. <br /> j - The analyte concentration is reported between the method detection limit and the lowest calibration point. The value reported is an estimate. <br /> J - The internal standard associated with the analyte is out of control limits. The reported concentration is an estimate. <br /> jl - The laboratory control sample(s) percent recovery and/or RPD were out of control limits. The reported concentration should be considered an estimate. js - The surrogate associated with the analyte is out of control limits. The reported concentration should be considered an estimate. <br /> k – The calibration results for the analyte were outside of acceptance criteria, biased high, and the analyte was not detected in the sample. <br /> lc - The presence of the analyte is likely due to laboratory contamination. <br /> L - The reported concentration was generated from a library search. <br /> nm - The analyte was not detected in one or more of the duplicate analyses. Therefore, calculation of the RPD is not applicable. <br /> pc - The sample was received with incorrect preservation or in a container not approved by the method. The value reported should be considered an estimate. ve - The analyte response exceeded the valid instrument calibration range. The value reported is an estimate. <br /> vo - The value reported fell outside the control limits established for this analyte. <br /> x - The sample chromatographic pattern does not resemble the fuel standard used for quantitation.
The URL can be used to link to this page
Your browser does not support the video tag.