Laserfiche WebLink
department on or before the same deadline date as required by the planning commission. <br /> (Res.72-69 Reg.11 §2, 1972). <br /> 13.08.030 Preliminary plat map-Data required. <br /> Each preliminary plat map shall show the contour lines and approximate location of soil log <br /> holes.These holes must be flagged for easy location.(Res.72-69 Reg.11 §3, 1972). <br /> 13.08.040 Soil logs-Number and depth. <br /> A minimum of one soil log for each five acres shall be dug to a depth of seven feet.(Use <br /> separate sheet to report data.)This work shall be done by a soil tester-designer licensed in <br /> Kittitas County.(Res.72-69 Reg. 11 §4,1972). <br /> 13.08.050 Use with community water supply-Lot area. <br /> When a private septic tank system is planned in conjunction with a community water <br /> system,each lot supporting a single-family dwelling shall have a minimum of twenty-two <br /> thousand square feet(approximately one-half acre).(Res.72-69 Reg.11 §5, 1972). <br /> 13.08.060 Lots below minimum area-Public system required. <br /> Any lot less than twenty-two thousand square feet(approximately one-half acre)must be <br /> serviced by an active public sewer system or other sewage disposal system approved by <br /> the health department.(Res.72-69 Reg.11 §6, 1972). <br /> 13.08.070 Wells and septic tanks on same lot-Lot size. <br /> The minimum lot size shall be forty-three thousand five hundred sixty square feet <br /> (approximately one acre)where individual wells and septic tank systems are located on the <br /> same lot.Exception to this requirement shall be limited to zoning districts which allow one <br /> residential lot per gross acre in a platted subdivision.(Res.72-69 Reg. 11 §7, 1972). <br /> 13.08.080 Low mean ground water level unacceptable. <br /> Areas an which the mean ground water level is less than four feet from the top of the ground <br /> shall net be comisadered satisfactory for individual sewage disposal systerns.in lots that <br /> have low mean ground water levels less than four feet from the top of the ground shall not <br /> be considered satisfactory for individual sewage disposal systems unless the Health <br /> Officer obtains detailed site plans and approved OSS designs prior to final approval of <br /> subdivisions proposals to mitigate risks <br /> 13.08.090 Recording plat-Conditions precedent. <br /> Prior to recording of a plat,the following shall apply: <br /> 1. Where public water is available within one-half mile or less of any proposed plat, <br /> water shall be provided by this means.A letter from the water district,city or other <br /> 16 <br />