Ryegrass Limited Purpose Landfill and Balefill Closed Landfill <br />Groundwater and Leachate Sampling and Analysis Plan <br />Sa[titas County Solid Waste <br />bubbles. If bubbles are consistently present, discard the vial and replace with a new unused <br />container. <br />Table 3 shows sample bottle requirements and preservatives. The analytical laboratory will provide <br />the sample containers and necessary preservation. <br />2.1.2 Field Filtering <br />Samples collected for dissolved constituent analysis will be filtered through a 0.45-micron filter. The <br />filters will attach directly to the discharge tube of the sampling pump. The filter must be changed <br />between sample points, or more frequently if clogging occurs. <br />Where in -line filtration is not possible, prefiltration bottles may be used to collect the samples. <br />Unpreserved prefiltration bottles must be obtained from the laboratory with the sample coolers and <br />identified with the bottle request. Prefiltratlon bottles, used for vacuum or pressure filtering, will not <br />be used for more than one well. Prefiltration bottles must be unpreserved, as any acid preservative <br />will extract total metals and invalidate the dissolved metals results. The use of prefiltration bottles <br />must be noted on the Chain -of -Custody form in the comments section. Samples that have been field - <br />filtered must be noted on the Chain -of -Custody forms in the comments section. The laboratory will <br />note which samples require fi lering on the indiOdual bottle labels, <br />Samples from the springs will not be field filtered. <br />2.1.3 Leachate Sampling <br />The Balefill Landfill includes a leachate collection and treatment system where leachate from two <br />topographical low areas are routed to a pump station and pumped to two lined leachate evaporation <br />lagoons. Leachate pump totalizer readings are reported in gallons and tracked by Klttitas County <br />staff <br />Leachate sampling will be complete from the leachate pump system of the Balefill Landfill on an <br />annual basis during the first quarter events and analytes should be identical to the groundwater <br />quality parameters for the Balefill Landfill. Leachate samples will be collected with a peristaltic pump <br />and new polyethylene tubing. <br />The LPL does not have a leachate management system as it is an unlined facility. <br />Occasionally, leachate sampling may be necessary if water is present in the underdrain of the lined <br />leachate lagoons. These samples will be similarly collected with a peristaltic pump and new <br />polyethylene tubing or a new polyethylene bailer. <br />2.2 Field Measurements <br />2.2.1 Static Water Level Measurements <br />Water levels at each of the monitoring wells will be measured prior to the start of purging in order to <br />monitor changes in seasonal or long-term water elevations and groundwater flow directionsEach of <br />the monitoring wells will he allowed to equilibrate with atmosphefic pressure prior to recording the <br />static water level measurement. The static water levels will be used to produce the groundwater <br />contour map for each quarter, <br />April 2024 1553.1763.010 2-2 <br />P.avised May 2024 <br />