My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10-22-2024 CDS_Special SS Briefings
>
Meetings
>
2024
>
10. October
>
2024-10-22 8:00 AM - CDS Study Session
>
10-22-2024 CDS_Special SS Briefings
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/17/2024 11:25:36 AM
Creation date
10/17/2024 10:44:10 AM
Metadata
Fields
Template:
Meeting
Date
10/22/2024
Meeting title
CDS Study Session
Location
BoCC Auditorium
Address
205 West 5th Room 109 - Ellensburg
Meeting type
Special
Meeting document type
Supporting documentation
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
172
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ii. Section R105.32 Expiration of Application <br /> 1. If,after a plan review has been initiated,an application for building permit requires <br /> corrections,a letter will be sent notifying the applicant of those items necessary to <br /> complete the review of the application and that the application will expire 180 days from <br /> the date of notification if the corrections are not submitted or are not adequate to <br /> resolve the corrections items listed.The Building Official is authorized to grant one <br /> extension,not to exceed 365 days.The extension shall be requested in writing,prior to <br /> permit application expiration,and justifiable cause shall be demonstrated.If expired,the <br /> application becomes null and void and the deposit is forfeited. <br /> 2. After a plan review has been completed,a letter will be sent notifying the applicant that <br /> the permit is ready for issuance and that if not purchased 180 days from the date of <br /> notification,the application will expire.The Building Official is authorized to grant one <br /> extension,not to exceed 365 days.The extension shall be requested in writing,prior to <br /> permit expiration,and justifiable cause shall be demonstrated.If expired,the application <br /> becomes null and void and,the deposit is forfeited. <br /> iii. Section 112 Board of Appeals <br /> 1. All appeals shall be heard by the Kittitas County Hearings Examiner. <br /> 3. The most current edition of the International Mechanical Code(IMC),2018 6 itien,published by the International Code Council <br /> as adopted and amended by the State of Washington in Chapter 51-52 WAC;including the adoption of and amendments to <br /> the 281-8-most current edition of the International Fuel Gas Code(IFGC),the 201-7-most current edition of the National Fuel Gas <br /> Code(NFPA 54)and the 294-8-most current edition of the Liquefied Petroleum Gas Code(NFPA 58). <br /> 4. The nst current edition of the International Fire Code(IFC),2918-E published by the International Code Council as <br /> adopted and amended by the State of Washington in Chapter 51-54A WAC;including those standards of the National Fire <br /> Protection Association specifically referenced in the International Fire Code:PROVIDED,that,notwithstanding any wording in <br /> this code,participants in religious ceremonies shall not be precluded from carrying hand-held candles.The following <br /> appendices and amendments are specifically adopted: <br /> a. Appendices <br /> i. Appendix B:Fire Flow for Buildings <br /> ii. Appendix C:Fire Hydrant Locations and Distribution <br /> iii. Appendix D:Fire Apparatus Access Roads <br /> iv. Appendix E:Hazard Categories <br /> V. Appendix F:Hazard Ranking <br />
The URL can be used to link to this page
Your browser does not support the video tag.