ESR-2074 I Most Widely Accepted and Trusted Page 2 of 5 <br />feet (18.6 M) of enclosed area, except that the <br />SmartVENTf Stacking Model #1540-511 and <br />FloodVENTe Stacking Model #1540-521 must be <br />installed with a minimum of one FV for every <br />400 square feet (37.2 m2) of enclosed area. <br />Below the base flood elevation. <br />C With the bottom of the FV located a maximum of <br />12 inches (305.4 mm) above the higher of the final <br />grade or floor and finished exterior grade immediately <br />under each opening. <br />4.2 Flood Vent Sealing Kit <br />The Flood Vent Sealing Kit Model 1540-526 is used in <br />conjunction with FloodVENT® Model #1640-520. When <br />installed and tested in accordance with ASTM F-283, the <br />FV and Flood Vent Sealing Kit assembly have an air <br />leakage rate of less than 0.2 cubic feet per minute per <br />lineal foot (18.66 Ilmin per lineal meter) at a pressure <br />differential of 1 pound per square foot (50 Pa) based on <br />12.58 lineal feet (3,8 lineal meters) contained by the Flood <br />Vent Sealing Kit. <br />6.2 The Smart Vene FVs must not be used in the place <br />of "breakaway walls" in coastal high hazard areas, but <br />are permitted for use in conjunction with breakaway <br />walls in other areas. <br />6.0 EVIDENCE SUBMITTED <br />6.1 Data in accordance with the ICC-ES Acceptance <br />Criteria for Mechanically Operated Flood Vents <br />(AC364), dated August 2015 (editorially revised <br />October 2017). <br />6.2 Test report on air infiltration in accordance with ASTM <br />E283. <br />7.0 IDENTIFICATION <br />7.1 The Smart VENT models and the Flood Vent Sealing <br />Kit recognized in this report must be identified by a <br />label bearing the manufacturer's name (Smartvent <br />Products, Inc.), the model number, and the evaluation <br />report number (ESR-2074). <br />7.2 The report holder's contact information is the <br />following: <br />6.0 CONDITIONS OF USE SMART VENT PRODUCTS, INC. <br />e 430 ANDBRO DRIVE, KNIT 1 <br />The Small Vent FVs described in this report comply with, PITMAN, NEW JERSEY 0807i <br />or are suitable alternatives to what is specified in, those PITMAN, <br />N, NEW <br />codes listed in Section 1.0 of this report, subject to the www 4414 yr B corn <br />following flonditions: info{liasmarfirentcom <br />5.1 The Smart VerO FVs.must be installed in accordance <br />with this report, the applicable code and the <br />manufacturer's installation instructions. In the event of <br />a conflict, the instructions in this report govem. <br />TABLE 1—MODEL. SIZES <br />MODEL. NAME <br />MODEL NUMBER <br />MODEL SIZE (in.) <br />COVERAGE (sq. ft.) <br />FloodVE <br />1540-620 <br />15 !A' X 714" <br />20D <br />Smar1VENT <br />1540-510 <br />15314" X 73/4" <br />20D <br />FloodVENTO Overhead Door <br />1540-524 <br />1531i' X 7314' <br />200 <br />SmartVENT® Overhead Door <br />1540-514 <br />153/4" X 7314" <br />200 <br />Wood Wall FloodVENTO <br />1540-570 <br />14" X 83/4„ <br />200 <br />Wood Wall FloodVE Overhead Door <br />1540-574 <br />14" X 8314" <br />200 <br />SmadVENT® Stacker <br />1640-511 <br />16" X 16" <br />400 <br />FloodVento Stacker <br />1640-621 <br />Ion X iv, <br />400 <br />For SI: 1 inch = 25A MM; 1 square foot = m' <br />f <br />FIGURE 1-4MART VENT: MODEL 1540-610 <br />