0 <br />Encompass <br />ENGINEERING & SURVEYING <br />September 9, 2019 <br />Jerry Martens <br />Agent for Easton Ridge Company <br />P.O. Box 458 <br />Cie Elum, WA 98922 <br />RE: Easton Water District <br />Water Service to the Plat of Marian Meadows <br />Dear Mr. Martens, <br />This letter is being written in response to your letter to Easton Water District dated August 19, 2019. The <br />following is the District's response to the list of items requested within the letter to the District: <br />1. Acknowledgment that the District is finalizing an agreement (DEA) for use (we have received the <br />standard form draft but the has yet to be edited to address the Marion Meadows Project) <br />The District is currently working with their attorney (Richard Jonson) and District Engineer (Chad <br />Allen) in preparing the Developer Extension Agreement. Prior to finalizing the Developer <br />Extension Agreement, a meeting will be necessary with the Easton Ridge Company and the District <br />to discuss the required improvements to the water system and associated costs. <br />2. Within the DEA or attached as an addendum a scope of needed District Improvements for the District to <br />provide water service. <br />The District is currently modeling the water system based on the current site plan for the Plat of <br />Marian Meadows to confirm pipe size (s), reservoir elevation, etc. Based on the District's approved <br />Comprehensive Water Plan and previous models, it is anticipated the following improvements will <br />be required: <br />• A 30' diameter by 25' tall reservoir (132,100 gallons) will be required to be constructed <br />with an overflow elevation at 2,345. 00. The reservoir shall be a concrete Mt Baker Silo <br />tank or approved equal. In addition, provisions will be required to ensure the new reservoir <br />and existing reservoirs fall equally. This may require an altitude valve(s) and/or other <br />device. <br />• The internal water system within the Marion Meadows Plat will be required to be an 8 -inch <br />diameter looped piping system per District Standards with intertie connections to the <br />existing water mains located at Country Drive Road and E Sparks Way. In addition, an fl- <br />inch stub will be required near the east side of the Marion Meadows Plat for future <br />connection. <br />• The District's telemetry system will be required to be updated or replaced to provide <br />communication between the existing wells, existing reservoirs and proposed reservoir. <br />Western Washington Division <br />165 NE Juniper St., Ste 201, Issaquah, WA 98027 <br />Phone: (425) 392-0250 <br />wm,w.Enco mpassE S .net <br />Eastern Washington Division <br />407 Swiftwater Blvd, Cle Elum, WA 98922 <br />Phone: (509) 674-7433 <br />