Laserfiche WebLink
ESR-2074 | Mosl Widetv Accepted and Trusted Page 2 of 5 <br />feet (18.6 Jn') of enclosed area, excepl that the <br />SmartVENll Stacking Model #1540-511 and <br />FloodVENf Stacking Model #1540-521 must be <br />installed with a minimum of one FV for every <br />400 square teel (37.2 m2) of enclosed area. <br />r Below the base flood elevation. <br />r With the bottom of the FV located a maximum of <br />12 inches (305.4 mm) above the higher of the final <br />grade or floor and finished exterior grade immediately <br />under each opening. <br />4.2 Flood Vent Sealing Kit <br />The Flood Vent Sealinq Kit Model 1540-526 is used in <br />conjunction with FloodVEruT@ Model #1540-b20. When <br />installed and tested in accordance with ASTM E283, lhe <br />FV and Flood Venl Sealing Kit assembly have an air <br />leakage rate of less than 0.2 cubic feet per minute per <br />lineal foot (18.56 l/min per lineal meter) at a pressure <br />differential of 1 pound per square foot (50 Pa) based on <br />12.58 lineal feet (3.8 lineal meters) contained by the Flood <br />Vent Sealing Kit. <br />5.0 coNDrTtoNs oF usE <br />The Smart Vent@ FVs described in this report comply with, <br />or are suitable alternatives to whal is specified in, those <br />codes listed in Section 1.0 of this report, subject to the <br />following conditions: <br />5,1 The Smarl Vento FVs musl be installed in accordance <br />with this report, the applicable code and the <br />manufacturer's installation instructions. ln the event of <br />a conflict, the instructions in this report govern. <br />5.2 The Smart Vent@ FVs musl not be used in the place <br />of "breakaway walls" in coastal high hazard areas, bul <br />are permitted for use in conjunction wilh breakaway <br />walls in other areas. <br />7.2 <br />TABLE 1-MODEL SIZES <br />EVIDENCE SUBMITTED <br />Data in accordance with the ICC-ES Acceptance <br />Criieria for Mechanically Operated Flood Vents <br />(AC364), dated Augusl 2015 (editorially revised <br />October 2017). <br />Test reporl on air infiltration in accordance with ASTM <br />E283. <br />IDENTIFICATION <br />The Smart VENf models and the Flood Vent Sealing <br />Kil recognized in this report must be identified by a <br />label bearing the manufacturer's name (Smartvent <br />Products, lnc.), the model number, and the evaluation <br />report number (ESR-2074). <br />The reporl holder's contact information is the <br />following: <br />SMART VENT PRODUCTS, INC. <br />430 ANDBRO DRIVE, UNIT 1 <br />PITMAN, NEW JERSEY 08071 <br />(877) 441.8368 <br />www.smartvent.com <br />info@smartvent.Com, <br />6.0 <br />6.t <br />6.2 <br />7.0 <br />7.',| <br />For Sl: 1 inch = 25.4 mm: 1 square fool = <br />MODEL NAME MODEL NUMBER MODEL SIZE (in.)COVERAGE (sq. ft.) <br />FloodVENf 1 540-520 15s14" X 7114"200 <br />SmartVENf 1 540-51 0 15tle" x 7"1a"200 <br />FloodVENf Overhead Door 1540-524 1531e" x 731a"200 <br />SmartVENTo Overhead Door 1540-514 1s3lq" x73/r 200 <br />Wood Wall FloodVEN.l€1 540-570 14" X 831q"200 <br />Wood Wall FloodVENT@ Overhead Door 1540-574 14" X83?',200 <br />SmartVENT@ Slacker 1 540-51 1 16" X 16"400 <br />FloodVent@ Stacker 1540-521 16" X 16"400 <br />FIGURE 1-SMART VENT: MODEL 1540-510