Laserfiche WebLink
ESR -2074 I Most widely Accepted and Trusted Page 2 of 5 <br />feel (18.6 m2) of enclosed area, except that the 5.2 The Smart Ven? FVs must not be used in the place <br />SmartVENTe Stacking Model #1540-511 and of "breakaway walls" in coastal high hazard areas, but <br />FloodVENTe Stacking Model #1540-521 must be are permitted for use in conjunction with breakaway <br />installed with a minimum of one FV for every walls in other areas. <br />400 square feet (37.2 m2) of enclosed area. 6,0 EVIDENCE SUBMITTED <br />ra Below the base flood elevation. 6.1 Data in accordance with the ICC -ES Acceptance <br />■ With the bottom of the FV located a maximum of <br />12 inches (305.4 mm) above the higher of the final <br />grade or floor and finished exterior grade immediately <br />under each opening. <br />4.2 Flood Vent Sealing Kit <br />The Flood Vent Sealing Kit Model 1540-526 is used in <br />conjunction with FloodVENT® Model #1540-520. When <br />installed and tested in accordance with ASTM E283, the <br />FV and Flood Vent Sealing Kit assembly have an air <br />leakage rate of less than 0.2 cubic feet per minute per <br />lineal foot (18.56 Itmin per lineal meter) at a pressure <br />differential of 1 pound per square foot (50 Pa) based on <br />12.58 lineal feet (3.8 lineal meters) contained by the Flood <br />Vent Sealing Kit. <br />5.0 CONDITIONS OF USE <br />The Smart Vent® FVs described in this report comply with, <br />or are suitable alternatives to what is specified in, those <br />codes listed in Section 1.0 of this report, subject to the <br />following conditions: <br />5,1 The Smart Vente FVs must be Installed in accordance <br />with this report, the applicable code and the <br />manufacturer's installation instructions. In the event of <br />a conflict, the instructions in this report govern. <br />Criteria for Mechanically Operated Flood Vents <br />(AC364), dated August 2015 (editorially revised <br />October 2017), <br />6.2 Test report on air infiltration in accordance with ASTM <br />E283. <br />7.0 IDENTIFICATION <br />7.1 The Smart VENTe models and the Flood Vent Sealing <br />Kit recognized in this report must be identified by a <br />label bearing the manufacturer's name (Smartvent <br />Products, Inc.), the model number, and the evaluation <br />report number (ESR -2074). <br />7,2 The report holder's contact <br />following: <br />SMART VENT PRODUCTS, INC. <br />430 ANDBRO DRIVE, UNIT 1 <br />PITMAN, NEW JERSEY 08071 <br />(877) 441-8368 <br />www.smartyent.com <br />infoftmartvent,com <br />TABLE 1—MODEL SIZES <br />information is the <br />MODEL NAME <br />MODEL NUMBER <br />MODEL SIZE (in.) <br />COVERAGE (sq. ft.) <br />FloodVEN <br />1540-520 <br />1'5/," X /4. <br />200 <br />SmartVENT® <br />1540-510 <br />15314" X 73/4" <br />200 <br />FloodVENT® Overhead Door <br />1540-524 <br />153/4' X 7314' <br />200 <br />SmartVENTe Overhead Door <br />1540-514 <br />15314" X 7314 <br />200 <br />Wood Wall FloodVENT® <br />1540-570 <br />14" X 8314" <br />200 <br />Wood Wall FloodVEN"T'e Overhead Door <br />1540-574 <br />14" X 83/4' <br />200 <br />SmartVEN'T* Stacker <br />1540-511 <br />16" X 16" <br />400 <br />FloodVent® Stacker <br />1540-521 <br />16" X 16" <br />400 <br />For SI: 1 Inch = 25.4 mm; 1 square foot = m` <br />FIGURE 1—SMART VENT: MODEL 1540-510 <br />