My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
LP-21-00002 Suncadia Ph. 3 Div 17 Tumble Creek - Master File (Indexed)
>
Meetings
>
2021
>
10. October
>
2021-10-19 2:00 PM - 2:00pm Public Hearing
>
LP-21-00002 Suncadia Ph. 3 Div 17 Tumble Creek - Master File (Indexed)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/14/2021 1:54:14 PM
Creation date
10/14/2021 1:48:09 PM
Metadata
Fields
Template:
Meeting
Date
10/19/2021
Meeting title
2:00pm Public Hearing
Location
Commissioners' Auditorium
Address
205 West 5th Room 109 - Ellensburg
Meeting type
Regular
Meeting document type
Supporting documentation
Supplemental fields
Alpha Order
a
Item
Public Hearing to consider Suncadia Phase 3 Division 17 Tumble Creek LP-21-00002.
Order
1
Placement
2:00pm Public Hearing
Row ID
82507
Type
Hold Public Hearing
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
309
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C -24 Proposed building materials. design and other architectural and landscape features of the <br />MPR. including signage and lighting. shall be designed to help structures fit within the visual <br />setting. The developer shall in consideration of building design and materials address the need <br />for fire resistively in construction. Wildfires are spread via the radiant heat that is produced. <br />The use of fire resistive materials lessens the chance of wildfire spread. The MPR is in a high <br />fire danger area. <br />C-25 The applicant shall prepare. and submit to Kittitas County for approval, proposed <br />covenants. conditions and restrictions (CC&Rs) applicable to privately owned residential <br />units/buildings within the MPR. The CC&Rs shall address, at a minimum. the following <br />concerns: building materiaL color and design: limits on clearing open space portions of <br />individual lots: accessory buildings: landscaping requirements and limitations; lighting: policies <br />regarding domestic pets: storage and use of toxic or hazardous materials (e.g. pesticides, <br />herbicides): and maintenance. Some ofthese elements are expressly addressed in Exhibit J to the <br />Development Agreement. All CC&Rs shall be consistent with such Exhibit J. In addition, the <br />County shall ensure consistency of these elements of the CC&Rs with applicable policies in its <br />Comprehensive Plan: other elements of the CC&Rs are not subject to review by the County. The <br />applicant and County may address the above mentioned standards in the MPR Development <br />Agreement. The applicant shall add to the covenants list the following items: <br />(a) All building including private SFR single family residence. MFR multi family residence and <br />buildings required under the most current building code adopted. shall have approved tire <br />sprinklers installed, tested and maintained as listed in National Fire Protection Association <br />sections 13. 13D, 13R. <br />(b) All buildings shall have a defensible space requirement around each structure. Defensible <br />spaces shall be determined by application of formulas found in .;Recommendations for Fire <br />Safety and Prevention", dated March 1999, copies of which are available in the office of the <br />Kittitas County Fire Marshal. Defensible space around structures does not constitute a portion of <br />the developed area of a lot or parcel, and shall not be counted against any applicable lot coverage <br />restrictions. <br />(c) The Wildfire Hazard Severity Rating shall have the following additional adjustment factors'' <br />• Fire sprinklers in structures-subtract three (3) points: and <br />• External underground sprinklers-subtract one (I) point. <br />d) Overall vvildfire rating for the MPR: <br />Point Totals <br />Low = 0-15 points <br />Moderate= 15-30 points <br />High= 30-45 points <br />Extreme = 45+ points <br />Suncadia MPR Conditions of Approval <br />December 2, 2008 <br />Defensible space distance from structures <br />10 feet <br />20 feet <br />25 feet <br />30 feet+ <br />Page 27 <br />Index #32
The URL can be used to link to this page
Your browser does not support the video tag.