Laserfiche WebLink
ELEVATION CERTIFICATE OMB No.1660-OD08 <br />Expiration Date: November 30, 2022 <br />IMPORTANT: In !hese spaces, copy the corresponding Information from Section A. FOR INSURANCE COMPANY USE <br />Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: <br />8160 SR 970 <br />City Slate ZIP Code Company NAIC Number <br />Cie Elum Washington 98922 <br />SECTION G —COMMUNITY INFORMATION (OPTIONAL) <br />The local official who Is authorized by law or ordinance to administer the community's floodplain management ordinance can complete <br />Sections A, B. C (or E), and G of this Elevation CeffftWe. Complete the applicable item(s) and sign below. Check the measurement <br />used in Items G8—G10. In Puerto Rico only, enter meters, <br />G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, <br />engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation <br />data in the Comments area below.) <br />()2.❑ A community official completed Section E for a building located in Zone A (without a FEMA -issued or community -issued BFE) <br />or Zone AO. <br />G3. [E The following information (Items G4—G10) is provided for community floodplain management purposes. <br />G4. Permit Number G5, Date Permit Issued G6. Date Certificate of <br />Compliance/Occupancy Issued <br />FD -19-00011 4-26-2019 09-29.2020 <br />G7. This permit has been issued for: Q New Construction ❑ Substantial Improvement <br />G8. Elevation of as -built lowest floor (including basement) 1$84.7 ❑ Datum <br />of the building: ❑x feet meters NGVD 19 <br />G9. BFE or (in Zone AO) depth of flooding at the building site: 1879.5 Z feet ❑ meters Datum NGVD 29 <br />G10. Community's design flood elevation: 1879.5 ❑ feet ❑ meters Datum NGVD 29 <br />Local Official's Name True <br />Arden Thomas Water Resource Manager <br />Community Name Telephone <br />Kittitas County (509) 962-7523 <br />Signature Date <br />09-29-2020 <br />Comments (including type of equipment and location, per C2(e), if applicable) <br />The building includes a crawispace, but there is not a fully enclosed space below the base flood elevation (the top of the bottom floor <br />and the lowest and highest adjacent grade elevations are all above the base flood elevation). Flood vents (AB.b-c) are not required, per <br />Kittitas County Code 14.08, because the crawlspace is determined to not be subject to flooding since the top of the bottom floor and the <br />lowest and highest adjacent grade elevations are all above the base flood elevation (KCC 14.08.250.2 - Fully enclosed areas below the <br />lowest floor that are subject to flooding are prohibited, or shall be designed to automatically equalize hydrostatic and hydrodynamic <br />flood forces on exterior walls by allowing for the entry and exit of flood waters). <br />❑ Check here if attachments. <br />FEMA Form 086-0-33 (12119) Replaces all previous editions. Form Page 4 of 6 <br />