Laserfiche WebLink
Each subsequent sheet shall have space for the County Engineer to initial and date the sheet as follows: <br />Initials -County Engineer Date <br />Drawing Scale: Standardized engineering scales shall be used. The scales listed below are the minimum. <br />More detailed scales shall be required by the county where additional drawing detail is needed. <br />1. Plan and profile plans: Horizontal 1"=50', Vertical 1 "=5'. <br />2. Overall site plans may range from 1 "=50' to 1 "=100'. <br />3. Detail views maybe shown at a convenient scale, normally 1"= 10' or 1"=20'. <br />Seal and Signature: The seal and signature of the developer's engineer, under whose supervision the <br />plans were prepared, shall be located next to the acceptance block on each sheet. <br />Utilities: The type, size, location and number of all above ground and underground utilities shall be <br />shown. Field verified elevations and locations may be required on the construction plans for all <br />underground utilities that are critical to the design or that may substantially affect the design or <br />construction. It will be the responsibility of the contractor to verify the existence and location of all <br />underground utilities along their route of work prior to commencing any new construction. Field located <br />utilities not shown on accepted construction plans shall be added to the record (as -built) drawings. <br />Private Improvements: Private improvements such as roadways, driveways, utilities, etc. shall be <br />clearly shown, labeled, and delineated from public roads and roads intended for acceptance into the <br />County system, on each sheet of the construction plans. The note below shall appear on the cover <br />sheet of the construction plans for private improvements: <br />Kittitas County shall not be responsible for the maintenance of roadway and appurtenant improvements, <br />including storm drainage structures and pipes, for the following private roads: (list). <br />Typical Sections: Typical roadway cross section for all roadways, existing or proposed, within and <br />adjacent to the proposed development. The typical sections shall appear on the detail sheet, or if no detail <br />sheet has been used, on the first sheet of the submittal showing roadway design. They shall indicate the <br />following: <br />A. Type of roadway(s), per KCC 12.03 Roadway Classification, <br />B. Profile grade design point (centerline, flow -line, top of curb, lip of gutter, etc.) <br />C. Pivot point for super elevations, <br />D. Dimensions for: roadway width, lane width, shoulder width, right-of-way location and width, <br />sidewalk width, planter strip width, cut and fill slopes, cross slope of finished grade surfaces, cross <br />Title 12 Kittitas County Code I Draft No. 5— Working Draft for Adoption 6/.12/2018 <br />85 <br />