Laserfiche WebLink
Action Item <br />IV. Mechanical Items: <br />A. If heat is added to the Bloom Pavilion, the energy code will require that insulation is <br />added. Patti will check with the city to see if they will grant an exemption to the <br />insulation requirement if the heat is only enough to maintain a 40° space. <br />B. Ventilation: <br />1. The existing roof -mounted exhaust fan is very noisy and must be turned off <br />during events that use the PA System. <br />2. The engineer has proposed two roof fans with low sidewall intake louvers for <br />ventilation. <br />V. Structural: <br />A. The roof of the addition can be self-supporting or possibly attached to the pavilion <br />structure. Attaching to the pavilion structure eliminates the need for a row of columns <br />along the pavilion wall. <br />B. Patti will look for information on the existing pavilion's structure that is needed to <br />evaluate the feasibility of using the existing structure to support the addition. <br />Information needed is the steel frame design, tilt -up concrete panel design, and <br />footing and foundation design. <br />VI. Electrical: <br />A. It was noted that the pavilion needs an upgraded electrical service. Multiple fans <br />running in the space frequently causes the breakers to trip. <br />ALSC B. ALSC will have the electrical engineer evaluate the existing electrical service to <br />determine what is needed to correct the situation. <br />C. LED lights are the preferred lighting source for the addition. <br />VII. Wash Racks: <br />A. Swine: 12 stations 3 ft. wide by 4 ft. deep are needed with a hose bib 5 ft. above the <br />slab at each station. <br />B. Cattle: 6 stations 6 ft. wide by 8 ft. deep are needed with a hose bib 5 ft. above the <br />slab at each station. <br />C. Horse: 6 — 12, 6 ft. wide by 8 ft. deep stations are needed with a hose bib 5 ft. above <br />the slab at each station. The rack should be as large as possible between the east <br />door to the Draft Horse Barn and the Drive Lane to the south. It should have roof with <br />a minimum clearance of 8 ft. and solid sides to reduce wind. <br />D. Wash racks should be paved with concrete. They will be covered with rubber mats. <br />E. No dividers are required between wash rack stations. <br />VIII. The City of Ellensburg will be responsible for plan review and permits for this project. <br />IX. The next meeting will be scheduled after the survey is complete. This may three — six <br />weeks. <br />2016-075 Kittitas Valley Event Center -Bloom Pavilion MM 2017-02-13 2 ALSC Architects I We bring our clients' stories to life. <br />