Laserfiche WebLink
Printed:6/27/2ûlé 2:4û:56 PM Q-2260-16.sbs Page 16 of 26 <br />New Building B -EWB Lean-to Continued... <br />Accessories on Roof/Wall <br />Open Areas <br />Type Fuli Height Left Jamb Yes Supcort Beam <br />Open For Wind Left Jamb Flash Yes Not by Manufacturer <br />%Open For Wind 100.00 %Right Jamb Yes <br />Material Thickness N/A Right Jamb Flash Yes <br />Material Weight 0.000 psf Header Flash Type N/A <br />Masonry Type NIA Flash Color SIG -200 TBD <br />Masonry Reinforcement N/A Height 16'-0" <br />Shear Wall No Width 25'-0" <br />Deduct Liner Panel Yes Distance Steelline to Material O'-0" <br />Deduct Insulation Yes Distance Steelline to Beam O'-0" <br />Cols.Braced by Mas'y/Tilt-up No Elevation AWillAreabeSheetedinFutureYesBay1 <br />Distance From Left Column O'-0" <br />Distance From Left Steelline O'-0" <br />Type Full Height Left Jamb Yes Support Beam <br />Open For Wind Left Jamb Flash Yes Not bv Manufacturer <br />%Open For Wind 100.00 %Right Jamb Yes <br />Material Thickness N/A Right Jamb Flash Yes <br />Material Weight 0.000 psf Header Flash Type NIA <br />Masonry Type N/A Flash Color SIG -200 TBD <br />Masonry Reinforcement N/A Height 16'-0" <br />Shear Wall No Width 152'-4" <br />Deduct Liner Panel Yes Distance Steelline to Material O'-O" <br />Deduct Insulation Yes Distance Steelline to Beam O'-0" <br />Cols.Braced by Mas'y/Tilt-up No Elevation B <br />Will Area be Sheeted in Future Yes Bay 1 <br />Distance From Left Column O'-0" <br />Distance From Left Steelline O'-0" <br />Type Full Height Left Jamb Yes Suwpori:Beam <br />Open For Wind Left Jamb Flash Yes Not by Manufacturer <br />%Open For Wind 100.00 %Right Jamb Yes <br />Material Thickness N/A Right Jamb Flash Yes <br />Material Weight 0,000 psf Header Flash Type N!A <br />Masonry Type N/A Flash Color SIG -200 TBD <br />Masonry Reinforcernent N/A Height 16'-0" <br />Shear Wall No Width 25'-0" <br />Deduct Liner Panel Yes Distance Steelline to Material O'-0" <br />Deduct Insulation Yes Distance Steelline to Beam O'-0" <br />Cols.Braced by Mas'y/Tilt-up No Elevation C <br />Will Area be Sheeted in Future Yes Bay 1 <br />Distance From Left Column O'-0" <br />Distance From Left Steelline O'-0" <br />Type Child Bldg Attachment Left Jamb No Suunort Beam <br />Open For Other Left Jamb Flash No Not by Manufacturer <br />%Open For Wind 0.00 %Right Jamb No <br />Material Thickness NIA Right Jamb Flash No <br />Material Weight 0.000 psf Header Flash Type N!A <br />Masonry Type N/A Flash Color N/A <br />Masonry Reinforcement N!A Height 22'-3" <br />Shear Wall No Width 152'-4" <br />Deduct Liner Panel Yes Distance Steelline to Materia!C'-O" <br />Deduct Insulation Yes Distance Steelline to Beam O'-0" <br />Cols.Braced by Mas'y/Tilt-up No Elevation D <br />Will Area be Sheeted in Future N/A Bay 1 <br />Distance From Left Column O'-0" <br />Distance From Left Steelline O'-0" <br />*Nole -Deduct Panel Only Open Area constitutes panels provided by others and shall be structurally equal to Manufacturer's PBR panel.Panel attachment is NOT byManufacturer. <br />*Note -Girts and panels for child building(s)have been removed at common area(s) <br />Gutters <br />Type Noithern Large Elevation B <br />Quantity 1 .Bay 1 <br />Length 152'-4"Distance from Left Column O'-0" <br />Distance from Left Steelline O'-0" <br />Gutters (List)Total