Laserfiche WebLink
Printed:6/27/2016 2:40:56 PM Q-2260-16.sbs Page 9 of 2 <br />New Building A -350'x200'x16'Continued.. <br />Accessories on Roof/Wall Continued... <br />Distance From Left Steelline O'-0" <br />Support Beam <br />Not by Manufacturer <br />Type Full Height Left Jamb No Support BeamOpenForWindLeftJambFlashNoNotbyManufacturer <br />%Open For Wind 100.00 %Right Jamb No <br />Material Thickness N/A Right Jamb Flash No <br />Material Weight 0.000 psf Header Flash Type NIA <br />Masonry Type N/A Flash Color N/A <br />Masonry Reinforcement N/A Height 16'-0" <br />Shear Wall No Width 23'-10" <br />Deduct Liner Panel Yes Distance Steelline to Material O'-0" <br />Deduct Insulation Yes Distance Steelline to Beam O'-0" <br />Cols.Braced by Mas'y/Tilt-up No Elevation D <br />Will Area be Sheeted in Future Yes Bay 1 <br />Distance From Left Column O'-0" <br />Distance From Left Steelline O'-0" <br />Type Attachment Height Left Jamb No Support BeamOpenForWindLeftJambFlashNoNotbyManufacturer%Open For Wind 100.00 %Right Jamb No <br />Material Thickness N/A Right Jamb Flash No <br />Material Weight 0.000 psf Header Flash Type N/A <br />Masonry Type N/A Flash Color NIA <br />Masom y Reinforcement N/A Height 22'-3" <br />Shear Wall No Width 152'-4" <br />Deduct Liner Panel Yes Distance Steelline to Material O'-0" <br />Deduct Insulation Yes Distance Steelline to Beam O'-0" <br />Cols.Braced by Mas'y/Tilt-up No Elevation D <br />Will Area be Sheeted in Future Yes Bay 1 <br />Distance From Left Column 23'-10" <br />Distance From Left Steelline 23'-10" <br />Type Full Height Left Jamb No Support BeamOpenForWindLeftJambFlashNoNotbyManufacturer%Open For Wind 100.00 %Right Jamb No <br />Material Thickness N/A Right Jamb Flash No <br />Material Weight 0.000 psf Header Flash Type N/A <br />Masonry Type N/A Flash Color N/A <br />Masonry Reinforcement N/A Height 16'-0" <br />Shear Wall No Width 23'-10" <br />Deduct Liner Panel Yes Distance Steelline to Material O'-0" <br />Deduct Insulation Yes Distance Steelline to Beam O'-0" <br />Cols.Braced by Mas'y/Tilt-up No Elevation D <br />Will Area be Sheeted in Future Yes Bay 8 <br />Distance From Left Column 1'-2" <br />Distance From Left Steelline 176'-2" <br />*Note -DedLict Panel Only Open Area constitutes panels provided by others and shall be structurally equal to Manufacturer's PBR panel Panel attachment is NOT byManufacturer. <br />Gutters <br />Type Northern Large Elevation A <br />Quantity 1 Bay 1 <br />Length 300'-0"Distance from Left Column O'-0" <br />Distance from Left Steelline O'-0" <br />Type Northern Large Elevation C <br />Quantity 1 Bay 1 <br />Length 300'-0"Distance from Left Column O'-0" <br />Distance from Left Steenine O'-0" <br />Gutters (List)Total <br />Downspouts <br />Quantity 5 Elevation A <br />Length 16'-0" <br />Elbow Yes <br />Trim SIG -200 TBD <br />Quantity 5 Elevation C <br />Length 16'-0" <br />Elbow Yes <br />Trim SIG -200 TBD <br />Downspouts (List)Total