My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Agreement
>
Meetings
>
2016
>
02. February
>
2016-02-02 10:00 AM - Commissioners' Agenda
>
Agreement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/13/2018 12:06:37 PM
Creation date
6/13/2018 12:03:11 PM
Metadata
Fields
Template:
Meeting
Date
2/2/2016
Meeting title
Commissioners' Agenda
Location
Commissioners' Auditorium
Address
205 West 5th Room 109 - Ellensburg
Meeting type
Regular
Meeting document type
Fully Executed Version
Supplemental fields
Alpha Order
f
Item
Request to Approve an Agreement between General Pacific and Kittitas County for the Purchase of Water Meter Reading Equipment and Software
Order
6
Placement
Consent Agenda
Row ID
27695
Type
Agreement
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPECIFICATIONS FEATURES <br />..-- <br />Dimensions 5.125" (H); 1.75" (W) at top; Communication Type Two-Way <br />2.125" (W) at bottom Application Type Control/Monitor <br />Broadcast Frequency FCC regulated 902-928 MHz <br />MHz Band frequency hopping modulation Reading Interval Type Midnight/Now <br />Operating Temperature -400 <br />... 60 0 C (-40 0 <br />... 140 0 F) <br />Range -Storage and based on storage and meter reading. <br />Encoder Compatibility Absolute/Incremental <br />Mobile Reading ../ <br />Meter Reading RF output may be reduced by Migratable to Fixed Network * extremely low temperatures. The <br />water meter should not be subjected Premise Leak Detection ../ <br />to temperatures below freezing. Cut-Wire Indication ../ <br />Humidity 0% ... 100% condensing <br />Reverse Flow Indication ../ <br />Battery One (1) lithium thionyl chloride (Absolute Encoder) <br />C cell (nonreplaceable) f- <br />No Usage Indication ../ <br />Battery Life 20 years (calculated) <br />Endpoint/Encoder or Badger Meter 308 connector with <br />E-Series Ultrasonic 6-, 25-or 75-foot lead length <br />Encoder Error ../ <br />(Absolute Encoder) <br />Meter Assembly Low Battery Indication ../ <br />Endpoint Only 3-, 10-,25-or 75-foot lead length Remote Programming ../ <br />prewired <br />Remote Clock ../ <br />Synchronization <br />Firmware Upgrades ../ Construction: All ORION Migratable endpoints are housed in an <br />engineered polymer enclosure with an ORION RF board, battery <br />and antenna. To assure long-term performance, the enclosure is <br />fully potted to withstand harsh environments and to protect the <br />electronics in flooded or submerged pit applications. <br />* Can be upgraded with migration license. <br />Range: Transmission reception depends on a number of factors: <br />topographical features, a building's construction materials and <br />obstacles such as buildings, trees, vegetation and fences. <br />Temporary conditions, such as a vehicle parked near the endpoint <br />or heavy rain or snow, could also affect reception. These factors <br />need to be considered when installing and communicating with <br />the endpoint using a handheld or mobile reading system. For a <br />more in-depth discussion, see the white paper, Understanding RF <br />Propagation of AMRIAMI Systems, available at www.badgermeter.com . <br />License Requirements: ORION Migratable endpoints comply with Part 15 of the FCC Rules. No license is required by the utility to operate an ORION meter reading system. <br />Transportation: The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. The ORION endpoint is considered <br />an operating transmitter and cannot be shipped by air. <br />Caution: Changes or modifications to the equipment that are nat expressly approved by Badger Meter could void the user's authorityta operate the equipment <br />Making WaterVisible® <br />E-Series, M-Series, Making Water Visible, ORION and Recordall are registered trademarks of Badger Meter, Inc. Other trademarks appearing in this document are the property of their <br />respective entities Due to continuolls research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without <br />notice, except to the extent an outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved. <br />www.badgermeter.com <br />The Americas 1 Badger Meter 14545 West Brown Deer Rd 1 PD Box 2450361 Milwaukee, WI 53224-95361800-876-38371414-355-0400 <br />Mexico I Badger Meter de las Americas, S.A. de (.V.I Pedro Luis Ogazon W321 Esq. Angelina W241 Colonia Guadalupe Inn I CP 01 050 I Mexico, OF I Mexico 1+52-55-5662-0882 <br />Europe, Middle East and Africa I Badger Meter Europa GmbH I Nurtinger Str 76172639 NeuFfen I Germany 1 +49-7025-9208-0 <br />Europe, Middle East Branch Office I Badger Meter Europe I PO Box 3414421 Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C2091 Dubai / UAE I +971-4-3712503 <br />Czech Republic I Badger Meter Czech Republic s.r.o.1 MafikoWI 708)/)6 i fi)1 0081110, C7ech Repuhlic I ;-4)0-)-414).0<111 <br />Slovakia I Badger Meter Slovakia s.r.o.1 Racianska 109/81831 02 Bratislava, Slovakia I +421-2-44638301 <br />Asia Pacific 1 Badger Meter 180 Marine Parade Rd 1 21-06 Parkway Parade I Singapore 4492691 +65-63464836 <br />China I Badger Meter 17-1202199 Hangzhong Road I Minhang District I Shanghai I China 201 1 01 1+86-21-57635412 Legacy Document Number: Excerpt from ORI-DS-00197-EN
The URL can be used to link to this page
Your browser does not support the video tag.